2754341

5015A Phoenix Contact GmbH & Co. Postfach 1341 32819 Blomberg Germany
1
INTERBUS-S
Product Description
The IBS ST 24 BK-T bus
terminal module is the head
station for an INTERBUS ST
compact station in an
INTERBUS-S network.
Features
- INTERBUS-S protocol
- D-SUB 9 remote bus
connectors
- Electrical isolation of the
remote bus segments
- Electrical isolation of the logic
and I/O voltage
- Diagnostic LEDs
- Alarm output
- Reconfiguration input
- Replaceable electronics
- Rail mountable
(EN 50022)
Applications
Connection of an INTERBUS ST
compact station to the
INTERBUS-S remote bus.
IBS ST 24 BK-T
Data Sheet
Bus Terminal Module
08/1994Data Sheet Revision A
Fig. 1: IBS ST 24 BK-T
50152001
5015A Phoenix Contact GmbH & Co. Postfach 1341 32819 Blomberg Germany
2
Example of an Electrical Installation
Fig. 2: Exemplary connection of an IB ST compact station through the IBS ST 24 BK-T bus
terminal module to the INTERBUS-S remote bus. An IB ST compact station may consist
of up to 8 I/O modules.
Table 1: Ordering data
Description Type Order No.
Bus terminal module IBS ST 24 BK-T 27 54 34 1
Module electronics, separately IBS STME 24 BK-T 27 54 36 7
Terminal block, separately IBS STTB 24 BK-T 27 53 18 0
Fuse, 1 A, slow-blow IBS TR5 1AT 28 06 60 0
Insertion bridge, 80-pos., divisible, IN = 26A,
insulated back (5 pieces)
EB 80-DIK BU (blue)
EB 80-DIK RD (red)
27 15 94 0
27 15 95 3
Zack (“quick“) strip for terminal labeling ZB 6 ... see Phoenix Contact Catalog, Part 3
MARKING, MOUNTING, Page 18
Mounting rail EN 50022, 2 meters NS 35/7,5 perforated
NS 35/7,5 unperforated
08 01 68 1
08 01 73 3
Incoming remote bus Outgoing remote bus
PE
50152004
ST cable
Connect the mounting rail via ground terminals with protective earth (PE), as the
modules are grounded when they are snapped onto the rail.
5015A Phoenix Contact GmbH & Co. Postfach 1341 32819 Blomberg Germany
3
Connection
Fig. 3: Connection of the supply voltage
U
L
: Supply voltage for the bus logic
U
A
: Supply voltage for the alarm contact (optional)
Fig. 4: Method of functioning of the alarm contact
U
REC
: Supply voltage for the reconfiguration input (optional). This input can only be used in
connection with a group definition. The reconfiguration input has the same potential as
the supply voltage. That means that the terminals 9 and 16 have to be connected.
UL RC BA E LD RD
914
13 15
4
12
8
6
16
1
5
7
50272002
U
A REC
U
+
+
+
U
L
Internally
connected
To be wired
externally
Alarm not set and
INTERBUS-S is connected
Alarm set
50151006
1514
6
1514
6

2754341