IRK.41, .56 Series
7
Bulletin I27131 rev. G 10/02
www.irf.com
Fig. 11 - Current Ratings CharacteristicsFig. 10 - Current Ratings Characteristics
70
80
90
100
110
120
130
0 10203040506070
Maximum Allowable Case Temperature (°C)
30°
60°
90°
120°
180°
Average On-state Current (A)
Conduction Angle
IRK.56.. Series
R (DC) = 0.40 K/W
thJC
70
80
90
100
110
120
130
0 20406080100
DC
30°
60°
90°
120°
180°
Average On-state Current (A)
Maximum Allowable Case TemperatureC)
Conduction Period
IRK.56.. Series
R (DC) = 0.40 K/W
thJC
Fig. 14 - Maximum Non-Repetitive Surge Current
Fig. 15 - Maximum Non-Repetitive Surge Current
Fig. 13 - On-state Power Loss Characteristics
Fig. 12 - On-state Power Loss Characteristics
0
20
40
60
80
100
120
0 20 40 60 80 100
DC
180°
120°
90°
60°
30°
RMS Limit
Conduction Period
Maximum Average On-state Power Loss (W)
Average On-state Current (A)
IRK.56.. Series
Per Junction
T = 125°C
J
0
10
20
30
40
50
60
70
80
90
0 102030405060
180°
120°
90°
60°
30°
RMS Limit
Conduction Angle
Maximum Average On-state Power Loss (W)
Average On-state Current (A)
IRK.56.. Series
Per Junction
T = 125°C
J
500
600
700
800
900
1000
1100
1200
1 10 100
Number Of Equal Amplitude Half Cycle Current Pulses (N)
Initial T = 125°C
@ 60 Hz 0.0083 s
@ 50 Hz 0.0100 s
At Any Rated Load Condition And With
Rated V Applied Following Surge.
RRM
J
Peak Half Sine Wave On-state Current (A)
IRK.56.. Series
Per Junction
400
600
800
1000
1200
1400
0.01 0.1 1
Peak Half Sine Wave On-state Current (A)
Pulse Train Duration (s)
Maximum Non Repetitive Surge Current
Versus Pulse Train Duration. Control
Initial T = 125°C
No Voltage Reapplied
Rated V Reapplied
Of Conduction May Not Be Maintained.
J
RRM
IRK.56.. Series
Per Junction
IRK.41, .56 Series
8
Bulletin I27131 rev. G 10/02
www.irf.com
Fig. 16 - On-state Power Loss Characteristics
Fig. 17 - On-state Power Loss Characteristics
Fig. 18 - On-state Power Loss Characteristics
0 20406080100120140
Maximum Allowable Ambient Temperature (°C)
4
K
/
W
2
K
/
W
1
.
5
K
/
W
1
K
/
W
0
.
7
K
/
W
0
.
5
K/
W
0
.
3
K
/
W
R
=
0
.
1
K
/
W
-
D
e
l
t
a
R
t
h
S
A
0
.
2
K
/
W
0
.
4
K
/
W
0
20
40
60
80
100
120
140
160
180
200
0 20406080100120140
180°
120°
90°
60°
30°
Total RMS Output Current (A)
Maximum Total On-state Power Loss (W)
Conduction Angle
IRK.56.. Series
Per Module
T = 12C
J
0 20406080100120140
Maximum Allowable Ambient Temperature (°C)
2
K
/
W
1
K
/
W
R
=
0
.
1
K
/
W
-
D
e
l
t
a
R
th
S
A
0
.
7
K
/
W
0
.
5
K
/
W
0
.
3
K
/
W
0
.
2
K
/
W
0
50
100
150
200
250
300
350
400
450
0 20406080100120140
Total Output Current (A)
Maximum Total Power Loss (W)
180°
(Sine)
180°
(Rect)
2 x IRK.56.. Series
Single Phase Bridge
Connected
T = 125°C
J
0 20 40 60 80 100 120 140
Maximum Allowable Ambient Temperature (°C)
1
K
/
W
0
.
7
K
/
W
0
.
5
K
/
W
0
.
3
K
/
W
R
=
0
.
1
K
/
W
-
D
e
l
t
a
R
th
S
A
0
.
2
K
/
W
0
100
200
300
400
500
600
0 20 40 60 80 100 120 140 160 180
Total Output Current (A)
Maximum Total Power Loss (W)
120°
(Rect)
3 x IRK.56.. Series
Three Phase Bridge
Connected
T = 125°C
J
IRK.41, .56 Series
9
Bulletin I27131 rev. G 10/02
www.irf.com
Fig. 19 - On-state Voltage Drop Characteristics Fig. 20 - On-state Voltage Drop Characteristics
1
10
100
1000
0.5 1 1.5 2 2.5 3 3.5 4 4.5
T = 25°C
J
Instantaneous On-state Current (A)
Instantaneous On-state Voltage (V)
T = 125°C
J
IRK.56.. Series
Per Junction
1
10
100
1000
01234567
T = 25°C
J
Instantaneous On-state Current (A)
Instantaneous On-state Voltage (V)
T = 125°C
J
IRK.41.. Series
Per Junction
Fig. 23 - Thermal Impedance Z
thJC
Characteristics
Fig. 22 - Recovery Current CharacteristicsFig. 21 - Recovery Charge Characteristics
30
40
50
60
70
80
90
100
110
10 20 30 40 50 60 70 80 90 100
Maximum Reverse Recovery Current - Irr (A)
Rate Of Fall Of Forward Current - di/dt (A/µs)
100 A
50 A
I = 200 A
TM
20 A
10 A
IRK.41.. Series
IRK.56.. Series
T = 125 °C
J
100
150
200
250
300
350
400
450
500
10 20 30 40 50 60 70 80 90 100
100 A
50 A
Rate Of Fall Of On-state Current - di/dt (A/µs)
Maximum Reverse Recovery Charge - Qrr (µC)
I = 200 A
TM
20 A
10 A
IRK.41.. Series
IRK.56.. Series
T = 125 °C
J
0.01
0.1
1
0.001 0.01 0.1 1 10
Square Wave Pulse Duration (s)
thJC
Transient Thermal Impedance Z (K/W)
Per Junction
Steady State Value:
R = 0.46 K/W
R = 0.40 K/W
(DC Operation)
IRK.41.. Series
IRK.56.. Series
thJC
thJC

IRKT42/06A

Mfr. #:
Manufacturer:
Vishay
Description:
SCR DBL 2SCR 600V 40A ADD-A-PAK
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union