Spec No. JELF243A-9129B-01 P1/9
MURATA MFG.CO., LTD
Reference Onl
CHIP COIL(CHIP INDUCTORS)LQH2HPZ□□□□JRL SPECIFICATION
Murata Standard Reference Specification【AEC-Q200】
1. Scope
This reference specification applies to Chip coil (Chip Inductors) LQH2HPZ_JR series for Automotive Electronics based
on AEC-Q200 except for Power train and Safety.
2. Part Numbering
(ex) LQ H 2H P Z 220 M J R L
Product ID
Structure Dimension
Applications Category Inductance Tolerance Dimension Others
Packaging
(L×W)
and
(T)
L: Φ180Taping
Characteristics
3. Rating
・Operating Temperature Range.
(Ambient temperature; Self-temperature rise is not included) -40 to +105°C
(Product temperature; Self- temperature rise is included) -40 to +125°C
・Storage Temperature Range. -40 to +105°C
Customer
Part Number
Murata
Part Number
Inductance
DC
Resistance
(Ω)
Self
Resonant
Frequency
(MHz min)
Rated Current(mA)
ESD
5A:
8kV
(µH)
Tolerance
(%)
∗1 (Based on
inductance
change)
∗2 Based on
Temperature rise
∗3 Ambient
temperature
(85 )℃
∗4 Ambient
temperature
(105 )℃
LQH2HPZR47NJRL 0.47
N:±30
0.031±20% 190 3500 2750 1650
5A
LQH2HPZ1R0NJRL 1.0 0.048±20% 120 2600 2400 1440
LQH2HPZ1R2NJRL 1.2 0.055±20% 100 2450 2070 1240
LQH2HPZ1R5NJRL 1.5 0.075±20% 95 2200 1810 1080
LQH2HPZ2R2MJRL 2.2
M:±20
0.092±20% 50 1700 1650 990
LQH2HPZ3R3MJRL 3.3 0.13±20% 45 1450 1420 850
LQH2HPZ4R7MJRL 4.7 0.17±20% 40 1230 1290 770
LQH2HPZ6R8MJRL 6.8 0.26±20% 35 1050 1000 600
LQH2HPZ100MJRL 10 0.38±20% 30 830 830 490
LQH2HPZ150MJRL 15 0.55±20% 20 690 710 420
LQH2HPZ220MJRL 22 0.84±20% 20 530 540 320
∗1: When applied Rated current to the Products, Inductance will be within ±30% of intial inductance value range .
∗2:
Keep the temperature(ambient temperature plus self-generation of heat) under 125 . ℃
∗3: When applied rated current to the Products, temperature rise caused by self-generated heat shall be limited
to 40 max.℃ (Ambient temperature 85℃).
∗4:When applied rated current to the Products,temperature rise caused by self-generated heat shall be limited to 20 ℃
max. (Ambient temperature 85-105℃).
4. Testing Conditions
《Unless otherwise specified》 《In case of doubt》
Temperature : Ordinary Temperature (15 to 35°C) Temperature : 20 ± 2°C
Humidity : Ordinary Humidity (25 to 85 % (RH)) Humidity : 60 to 70 %
(RH)
Atmospheric Pressure : 86 to 106 kPa