MTA-B-03027 D (7/14)
5.3 ICC function
[1] Number and location of contacts on ICC
Number and location of contacts on ICC are specified in ISO/IEC 7816-2 figure 2.
[2] Applicable ICC
(1) Asynchronous card
1) Support ICC In conformity to ISO/IEC 7816-1/2/3(Default), EMV4.0 Level1
2) Protocol T=0 and T=1
(Automatic protocol type selection via ATR detection is
possible.)
3) Data byte reading/writing Inverse convention (MSB first, negative logic) and direct
convention (LSB first, positive logic) are available.
4) Clock during/after ATR *1 3.5712 MHz (F=372) (Default) / 7.1428 MHz (F=744)
(Conform to ISO / IEC 7816-3)
5) Communication speed 1etu = (F/D) x 1/f sec
D=1: (Default) / 2, 4: (Changeable by PPS)
6) Vpp Not connected
7) Vcc 5V / 3V (Type A and Type B)
(Automatic selection via T=15 of ATR detection is possible.)
8)
EMV Approval EMV4.0 Level 1 Approved (11757 0504 400 20 FIM)
(2) Synchronous card
1) Support ICC In conformity to ISO/IEC 7816-1/2/10,
SLE4442/4432/4428/4418
2) Vcc 5V
3) Vpp Not connected
*1 Answer To Reset
<Notice>
HITACHI-OMRON TERMINAL SOLUTIONS asks customers to check the performance of ICC
with HITACHI-OMRON TERMINAL SOLUTIONS standard ICC controller and FW in advance, if
ICC is special card. Because ISO standard and ICC(s) are subject to frequent modification.
HITACHI-OMRON TERMINAL SOLUTIONS supports you for capability of performing customer’s
ICC, provided with ICC and its specification.
5.4 SAM
[1] The following SAM controller is equipped with shipment. 1 SAM socket is mounted on the Main PCB.
And the additional 4 SAM socket are mounted on the additional PCB in V4KF-01JS-002 only.
- 1SAM : V4KF-01JS-001, V4KF-01JF-001
- 5SAM : V4KF-01JF-002
[2] SAM specification
1) Support SAM chip In conformity to ISO/IEC 7810(ID000), ISO/IEC 7816-1/2/3
2) Protocol T=0 and T=1
(Automatic protocol type selection via ATR detection is
possible.)
3) Data byte reading/writing Inverse convention (MSB first, negative logic) and direct
convention (LSB first, positive logic) are available.
4) Clock during/after ATR *1 3.5712 MHz(Conform to ISO / IEC 7816-3)
5) Communication speed 1etu = (372/D) x 1/(3.5712 x 10
6
) sec
D=1: (Default) / 2, 4: (Changeable by PPS)
6) Vpp Not connected
7) Vcc 5V/3V
(Automatic selection via T=15 of ATR detection is possible.)
5.5 Shutter function
[1] This shutter is equipped on the insertion slot of the C/R. It opens automatically by inserting the card. It
prevents foreign objects like dusts and coins from intruding to inside.
[2] This shutter should open by inserting the card that is more than 53.92mm in width.
MTA-B-03027 D (8/14)
5.6 Lock function
[1] Pin type lock mechanism is equipped to hold the card during operation of ICC in response to command
from host.
[2] This lock mechanism can be controlled by the command from the host.
[3] The condition of this lock mechanism can be checked by the command and response.
[4] This lock mechanism is released automatically at the power failure.
[5] This Lock mechanism works under the below conditions
(1) The card is inserted completely.
(2) The card does not exist inside of C/R.
5.7 Power Requirement
[1] Power supply voltage 10.8 – 13.2V DC (including ripple)
[2] Ripple of power supply 100mV (p-p) or less
[3] Power consumption (Input voltage: 12V DC)
In operation magnetic card 500mA or less
IC card 1.5A or less
In Standby 300mA or less
[4] Power supply connector
HIF3BD-10PA-254DS02 (2.54mm pitch HIROSE Japan) or equivalent (MIL-C-83503) is
mounted on C/R’s PCB.
Pin assignment of C/R (in/out direction view from the reader)
Pin No. Assigned signal IN/OUT Function
1 TXD OUT Transmit DATA
2 RXD IN Receive DATA
3 DTR OUT DATA Terminal Ready
4 CTS IN Clear to Send
5 SG - 0V
6 12V - Power
7 GND - Ground
8 12V - Power
9 GND - Ground
10 NC - Not Connect
(Cable with connector for Power supply and RS232 interface is not included)
<Pin Layout of connector>
[5] Power failure
1) Detection Voltage Less than 10.8V DC
2) Power failure process
In case of power failure, C/R deactivates the ICC and SAM chip(s), and releases the Lock.
5.8 Electrical interface
[1] Interface specification
(1) Electronic Interface RS232 interface
(2) Transmission Speed 1200, 2400, 4800, 9600, 19200, 38400 bps
(3) Synchronous Method Start-Stop synchronization Method
(4) Communication Method Half-duplex Method
(5) Pin Assignment Refer to the table in 5.7 Power Requirement
MTA-B-03027 D (9/14)
5.9 Software Interface
[1] Transmission protocols V4KF Series Card Reader Data Transmission Specification (Document
No. MTA-H-04015).
[2] Port to host Handling with a magnetic card, an IC card and SAM via single port
[3] Format A common APDU format is used for handling various ICC and SAM
[4] Downloadable All software are supported to be downloaded.
[5] Module Firmware is independently divided into every functional module (e.g.
ICC handling module, SAM handling module, etc)
and every module
can be independently downloaded
(regardless of order of download)
respectively.
5.10 LED Indicator
[1] One LED is equipped to inform the state of C/R and the reading result of the magnetic data.
[2] This LED can be indicated the three colors (green, red and orange).
[3] The specification of LED indicator can be controlled by the command from the host.
In detail, refer to
V4KF Series Card Reader Data Transmission Specification (Document No. MTA-H-04015).
5.11 Diagnostics function
[1] C/R provides the following functions as diagnostics of each module in the C/R.
This function is performed by pressing the white button located on the top of C/R just near SAM socket.
The test card is required to perform diagnostics. This function reports the following. *1
(1) OK/NG for Sensor Level
(2) OK/NG for Magnetic card reading
(3) OK/NG for LOCK mechanism
(4) OK/NG for ICC function
The SAM function is not worked.
[2] C/R indicates the result of the diagnostics by using LED indicator. *1
*1 In detail, V4KF Series Card Reader Data Transmission Specification (Document No.MTA-H-04015).
<Notice>
Make sure not to press this button, when the system is in operation.
6.
Environmental Condition
[1] Temperature
(1) In operation 0 to 55
(2) In storage -25 for 16 hours to 70 for 72 hours for non operation
and transport
[2] Humidity
(1) In operation 5 to 85% RH, no condensation and absolute air humidity of 23
g/m
3
or less
(2) In storage 5 to 90% RH, no condensation and absolute air humidity of 40
g/m
3
or less
7.
General performance
[1] Insulation Resistance 20MΩor more at 100V DC
(At normal temperature and humidity)
[2] Dielectric Strength 500V AC for 1minute
[3] Durable Vibration Frequency 10-150 Hz
Single vibration width 0.10mm
Acceleration 15m/s
2
Direction X,Y,Z
[4] Shock Endurance Acceleration 150m/s
2
Direction X,Y,Z

V4KF-01JF-001

Mfr. #:
Manufacturer:
Description:
CARD READER MAG SMCARD RS232 SQR
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union

Products related to this Datasheet