MPXV7007DPT1

MPXV7007
Rev 3, 10/2012
Freescale Semiconductor
Data Sheet: Technical Data
© 2005, 2009, 2011, 2012 Freescale Semiconductor, Inc. All rights reserved.
Pressure
Integrated Silicon Pressure Sensor
On-Chip Signal Conditioned,
Temperature Compensated and
Calibrated
The MPXV7007 series piezoresistive transducers are state-of-the-art
monolithic silicon pressure sensors designed for a wide range of applications,
but particularly those employing a microcontroller or microprocessor with A/D
inputs. This transducer combines advanced micromachining techniques, thin-
film metallization, and bipolar processing to provide an accurate, high level
analog output signal that is proportional to the applied pressure.
Features
5.0% Maximum Error Over 0 to 85C
Ideally Suited for Microprocessor or Microcontroller-Based Systems
Temperature Compensated Over –40 to +125C
Thermoplastic (PPS) Surface Mount Package
Patented Silicon Shear Stress Strain Gauge
Available in Differential and Gauge Configurations
ORDERING INFORMATION
Device Name
Package
Options
Case
No.
# of Ports Pressure Type
Device
Marking
None Single Dual Gauge Differential Absolute
Small Outline Package
MPXV
7007
DP
Trays
1351
MPXV
7007
DP
MPXV7007DPT1
Tape & Reel
1351
MPXV
7007
DP
MPXV7007GC6U
Rails
482A
MPXV
7007
G
MPXV
7007
GC6T1
Tape & Reel
482A
MPXV
7007
G
MPXV
7007
GP
Trays
1369
MPXV
7007
GP
Table 1. Pin Numbers
(1)
1.Pins 1, 5, 6, 7 and 8 are internal device connections. Do not connect to external circuitry or ground. Pin 1 is noted by the notch in the lead.
1 2 3 4 5 6 7 8
N/C V
s
Gnd V
out
N/C N/C N/C N/C
MPXV7007
Series
-7 to 7 kPa (-1 to 1 psi)
0.5 to 4.5 V Output
SMALL OUTLINE PACKAGE
MPXV7007GC6U/C6T1
CASE 482A-01
MPXV7007DP/DPT1
CASE 1351-01
MPXV7007GP
CASE 1369-01
Application Examples
Hospital Beds
•HVAC
Respiratory Systems
Process Control
MPXV7007
Sensors
2 Freescale Semiconductor, Inc.
Pressure
Operating Characteristics
Table 2. Operating Characteristics (V
S
= 5.0 Vdc, T
A
= 25°C unless otherwise noted. Decoupling circuit shown in Figure 3 re-
quired to meet specification.)
Characteristic Symbol Min Typ Max Unit
Pressure Range
(1)
1. 1.0 kPa (kiloPascal) equals 0.145 psi.
P
OP
-7 7 kPa
Supply Voltage
(2)
2. Device is ratiometric within this specified excitation range.
V
S
4.75 5.0 5.25 Vdc
Supply Current I
o
7.0 10 mAdc
Minimum Pressure Offset
(3)
(0 to 85C)
@ V
S
= 5.0 Volts
3. Offset (V
off
) is defined as the output voltage at the minimum rated pressure.
V
off
0.33 0.5 0.67 Vdc
Full Scale Output
(4)
(0 to 85C)
@ V
S
= 5.0 Volts
4. Full Scale Output (V
FSO
) is defined as the output voltage at the maximum or full rated pressure.
V
FSO
4.3 4.5 4.7 Vdc
Full Scale Span
(5)
(0 to 85C)
@ V
S
= 5.0 Volts
5. Full Scale Span (V
FSS
) is defined as the algebraic difference between the output voltage at full rated pressure and the output voltage at the
minimum rated pressure.
V
FSS
—4.0—Vdc
Accuracy
(6)
(0 to 85C)
6. Accuracy (error budget) consists of the following:
Linearity: Output deviation from a straight line relationship with pressure over the specified pressure range.
Temperature Hysteresis: Output deviation at any temperature within the operating temperature range, after the temperature is cycled to
and from the minimum or maximum operating temperature points, with zero differential pressure applied.
Pressure Hysteresis: Output deviation at any pressure within the specified range, when this pressure is cycled to and from the
minimum or maximum rated pressure, at 25C.
TcSpan: Output deviation over the temperature range of 0 to 85C, relative to 25C.
TcOffset: Output deviation with minimum rated pressure applied, over the temperature range of 0 to 85C, relative to
25C.
Variation from Nominal: The variation from nominal values, for Offset or Full Scale Span, as a percent of V
FSS
, at 25C.
———5.0 %V
FSS
Sensitivity V/P 286 —- mV/kPa
Response Time
(7)
7. Response Time is defined as the time for the incremental change in the output to go from 10% to 90% of its final value when subjected to
a specified step change in pressure.
t
R
—1.0-ms
Output Source Current at Full Scale Output I
O+
—0.1-mAdc
Warm-Up Time
(8)
8. Warm-up Time is defined as the time required for the product to meet the specified output voltage after the Pressure has been stabilized.
——20-ms
Offset Stability
(9)
9. Offset Stability is the product's output deviation when subjected to 1000 hours of Pulsed Pressure, Temperature Cycling with Bias Test.
——0.5 —- %V
FSS
MPXV7007
Sensors
Freescale Semiconductor, Inc. 3
Pressure
Maximum Ratings
Figure 1 shows a block diagram of the internal circuitry integrated on a pressure sensor chip.
Figure 1. Integrated Pressure Sensor Schematic
Table 3. Maximum Ratings
(1)
1. Exposure beyond the specified limits may cause permanent damage or degradation to the device.
Rating Symbol Value Unit
Maximum Pressure P
max
75 kPa
Storage Temperature T
stg
–40 to +125 C
Operating Temperature T
A
–40 to +125 C
Sensing
Element
Thin Film
Temperature
Compensation
and
Gain Stage #1
Gain Stage #2
and
Ground
Reference
Shift Circuitry
V
S
V
out
GND
Pins 1, 5, 6, 7, and 8 are NO CONNECTS
for Small Outline Package Device
2
4
3

MPXV7007DPT1

Mfr. #:
Manufacturer:
NXP / Freescale
Description:
Board Mount Pressure Sensors SOP DUAL PORT
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union