10
IX2R11
IXYS reserves the right to change limits, test conditions, and dimensions.
Figure 25
Figure 24
Quiescent Supply Currents vs. Supply Voltages
V
INL
, V
INH
= 0V
0
0.1
0.2
0.3
0.4
0.5
0.6
0.7
0.8
0.9
1
0 5 10 15 20 25 30 35 40
V
CL
, V
CH
, V
DD
Supply Voltage (V)
Supply Current (mA, uA)
I
CL
(mA)
I
CH
(mA)
I
DD
(uA)
Figure 26
LIN, HIN Input Bias Current vs. V
DD
Supply Voltage
0
2
4
6
8
10
12
14
16
18
20
0 5 10 15 20 25
V
DD
Voltage (V)
Input Bias Current (uA)
Figure 27
Figure 29
Figure 28
ENABLE Shutdown Delay vs. Temperature
V
DD
, V
CL
, V
CH
= 15V
0
20
40
60
80
100
120
140
-60 -40 -20 0 20 40 60 80 100 120 140
Temperature (C)
ENABLE Shutdown Delay (ns)
Low side
High side
Enable Threshold vs. V
DD
Logic Supply Voltage
Active Low Enable
0
2
4
6
8
10
12
14
16
18
5 10152025
V
DD
Supply Voltage (V)
ENABLE Threshold (V)
Postive Going
Outputs Disabled
Negative Going
Outputs Enabled
ENABLE Shut Off Delay vs. V
DD
Supply Voltage
60
70
80
90
100
110
120
130
0 5 10 15 20 25
V
DD
Supply Voltage (V)
Shut Down Delay (ns)
Low Side
High Side
V
CL
= 10V
V
CH
= 10V
V
CL
= 18V
V
CH
= 18V
V
CL
= 25V
V
CH
= 25,35V
V
CL
= 35V
Quiescent Supply Current vs. Temperature
V
DD
,V
CL
,V
CH
= 15V V
INL
, V
INH
= 0V
0
0.1
0.2
0.3
0.4
0.5
0.6
0.7
0.8
0.9
-100 -50 0 50 100 150
Temperature (C)
Quiescent Supply Current
V
CH
(mA)
V
CL
(mA)
V
DD
(uA)
11
IX2R11
© 2007 IXYS CORPORATION All rights reserved
Figure 33
Figure 32
Figure 30 Figure 31
High Level Ouput Voltage vs. Supply Voltage
V
HLGO
/ V
HHGO
= V
CL
- V
LGO
/ V
CH
- V
HGO
I
OUT =
20mA
0
0.05
0.1
0.15
0.2
0.25
0.3
0.35
0.4
0.45
5 101520253035
V
CL
, V
CH
(V)
High Level Ouput (V)
Low Level Output Voltage vs. Supply Voltage
V
LLGO
/ V
LHGO
= V
LGO
/ V
HGO
I
O
= 20mA
0
0.01
0.02
0.03
0.04
0.05
0.06
5 101520253035
V
CL
, V
CH
(V)
Low Level Output (V)
Under Voltage Lock Out vs. Temperature
Negative Going Trip Point
0
2
4
6
8
10
12
-100 -50 0 50 100 150
Temperature (C)
Under Voltage Trip Point (V)
V
CH
V
CL
Under Voltage Lock Out vs. Temperature
Positive Going Trip Point
0
2
4
6
8
10
12
-100 -50 0 50 100 150
Temperature (C)
Under Voltage Trip Point (V)
V
CH
V
CL
Figure 34
Figure 35
Output Source Current vs. Supply Voltage
0
1
2
3
4
5
6
0 5 10 15 20 25 30 35 40
V
CL
, V
CH
Supply Voltage (V)
Ouput Source Current (A)
Output Sink Current vs. Supply Voltage
-6
-5
-4
-3
-2
-1
0
0 5 10 15 20 25 30 35 40
V
CL
, V
CH
Supply Voltage (V)\
Ouput Sink Current (A)
12
IX2R11
IXYS reserves the right to change limits, test conditions, and dimensions.
Figure 36 Figure 37
Figure 38
Output Sourcing Current vs. Temperature
V
DD
, V
CL
, V
CH
= 15V
0
0.5
1
1.5
2
2.5
3
-100 -50 0 50 100 150
Temperature (C)
Source Output Current (A)
Output Sinking Current vs. Temperture
V
DD
, V
CL
, V
CH
= 15V
0
0.5
1
1.5
2
2.5
-100 -50 0 50 100 150
Temperature (C)
Output Sink Current (A)
Offset Leakage Current vs. High Side Offset Voltage
0
20
40
60
80
100
120
0 100 200 300 400 500 600 700
High Side Offset Voltage (V)
Leakage Current (uA)
Figure 39
Offset Leakage Current vs. Temperature
High Side Offset Voltage
= 600V
90
92
94
96
98
100
102
104
106
-100 -50 0 50 100 150
Temperature (C)
Offset Leakage Current (uA)

IX2R11S3T/R

Mfr. #:
Manufacturer:
Description:
IC DRVR HALF BRIDGE 2A 16-SOIC
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union