4
IX2R11
IXYS reserves the right to change limits, test conditions, and dimensions.
Symbol Definition Test Conditions Min Typ Max Units
t
on
Turn-on propagation delay C
load
= 1nF V
DD
, V
CL
,V
CH
=15V --- 140 170 ns
t
off
Turn-off propagation delay C
load
= 1nF V
DD
, V
CL
,V
CH
=15V --- 100 120 ns
t
enb
Enable delay, active low V
DD
=15V V
CL
,V
CH
=18V --- 90 110 ns
t
r
Turn-on rise time C
load
= 1nF V
CH,
V
CL
=15V --- 8 11 ns
t
f
Turn-off fall time C
load
= 1nF V
CH,
V
CL
=15V --- 7 10 ns
t
dm
Delay matching, HS & LS turn-on/off --- 30 40 ns
Symbol Definition Test Conditions Min Typ Max Units
V
INH
Logic “1” input voltage V
DD
,V
CL
,V
CH
=15V 9.5 9.8 --- V
V
INL
Logic “0” input voltage V
DD
,V
CL
,V
CH
=15V --- 5.8 6 V
V
HLGO
/
/ V
HHGO
High level output voltage, I
O
= 20mA --- 0.3 1 V
V
CH
-V
HGO
or V
CL
-V
LGO
V
LLGO
/
/ V
LHGO
Low level output voltage, I
O
= 20mA --- 0.04 0.1 V
V
HGO
or V
LGO
I
HL
HS to LS bias (leakage) current. V
HS
Offset = 600V --- 100 150 uA
I
QHS
Quiescent V
CH
supply current V
IN
= 0V, V
CH
=15V --- 700 1000 uA
I
QLS
Quiescent V
CL
supply current V
IN
= 0V, V
CL
=15V --- 160 300 uA
I
QDD
Quiescent V
DD
supply current V
IN
= 0V, V
DD
=15V --- 0.2 5 uA
I
IN
+ Logic “1” input bias current V
IN
= V
DD
= 15V --- 11 25 uA
I
IN
- Logic “0” input bias current V
IN
= 0V --- --- 1 uA
V
CHUV
+V
CH
supply under-voltage positive going threshold. 7 8.1 9 V
V
CHUV
-V
CH
supply under-voltage negative going threshold. 7 8 9 V
V
CLUV
+V
CL
supply under-voltage positive going threshold 9 9.9 11 V
V
CLUV
-V
CL
supply under-voltage negative going threshold. 8.2 9.2 10.5 V
I
GO
+ HS or LS output high short circuit sourcing current; V
GO
= 15V, PW<10us 2 2.5 --- A
I
GO
- HS or LS output low short circuit sinking current; V
GO
= 0V, PW<10us --- -2.5 -2 A
Dynamic Electrical Characteristics
*
Static Electrical Characteristics
* These characteristics are guaranteed by design only. Tested on a sample basis.