Data Sheet ADF5904
Rev. A | Page 13 of 15
INITIALIZATION SEQUENCE
After powering up the device, administer the initialization
sequence in Table 6 to set the register with the code to configure
the device.
Table 6. Initialization Sequence
Step Register Hex Code Description
1 R3 0x00000003 Reserved
2 R2 0x00020406 Temperature sensor to ATEST
3 R1 0x20001499 Configure Channel 1
4 R1 0x40001499 Configure Channel 2
5 R1 0x60001499 Configure Channel 3
6 R1 0x80001499 Configure Channel 4
7 R1 0xA0000019 Configure LO
8 R0 0x80007CA0 Power up
TEMPERATURE SENSOR
The on-chip temperature sensor of the ADF5904 is accessed on
the ATEST pin. The temperature sensor operates over the full
operating temperature range of −40°C to +105°C. To improve
accuracy, conduct a one-point calibration at room temperature
and store the result in the external memory. Convert the ATEST
voltage to temperature by using the following equation:
Temperature (°C) = (V
ATEST
− V
OFF
)/V
GAIN
where:
V
ATEST
is the voltage on the ATEST pin.
V
OFF
is the offset voltage and it is 1.212 V.
V
GAIN
is the voltage gain and it is 4.072e
−3
.