EE-SPZ301/401/W-01/W-02/Y-01 EE-SPZ301/401/W-01/W-02/Y-01
EE-1003 CONNECTOR EE-1003A CONNECTOR HOLDER
1,000±20
3±1
5.02.5
(3)
Black
(2)
White
(1)
Red
Two, 3.2 dia. holes
2.9
1
Terminal Arrangement
Note: Older standard colors are shown in
parentheses. The connector comes
with a 1-m attached cable.
1.75
(0.07)
11
(0.43)0.75
(0.03)
4.9
(0.19)
10.7
(0.42)
1.0
(0.04)
5.7
(0.22)
8
(0.31)
1.25
(0.05)
1.8
(0.07)
5
(0.20)
25.5
(1.00)
20
(0.79)
14.2
(0.56)
2.5
(0.10)
2
(0.08)
2
(0.08)
3.5
(0.14)
11
(0.43)
1
(0.04)
4.2
(0.17)
(3) Blue (Black) GND (O V)
(2) Black (White) OUTPUT
(1) Brown (Red) V
CC
recaut
ons
Refer to the Technical Information Section for general
precautions.
A fiber that has once been connected cannot be disconnected for
re-use.
A cable with a thickness of AWG24 min. and a length of 5 m max.
must be connected to the output terminals.
To use a cable longer than 5 m, attach a capacitor with a
capacitance of approximately 10
µ
F to the wires as shown below
(the distance between the terminal and the capacitor must be
within5m):
5mmax.
A capacitance of
10 µFmin.
5to24VDC
Extension cable
0V
OUT
Due to optical problems, the sensing distance of the EE-SPZ
must be a minimum of 1 mm, or malfunction will result.
Do not solder the cable to the connectors. Use the EE-1002
Connector or EE-1003 Connector (with a 1-m cable attached) to
connect the cable to the output terminals.
Use the EE-1003A Connector Holder to prevent accidental
disconnection of the EE-1003 Connector from the EE-SPZ
Photomicrosensor.
Do not impose excessive force on the terminals (refer to the
diagram below). Excess force will damage the terminals.
Terminal
No
If the metal mounting base is subjected to inductive electrical
noise, the photomicrosensor can be activated accidentally. If
noise is a problem, take the following precautions:
1. Connect the negative terminal to the mounting base to
ensure that there will be no difference in electric potential
between the photomicrosensor and mounting base.
2. Connect the negative terminal to the mounting base via a
0.47-
µ
F capacitor.
3. Insert a plastic insulating plate with a thickness of approxi-
mately 10 mm between the photomicrosensor and mounting
base.
Wire, as shown by the following illustration, to connect a small
inductive load (a relay for example) to the photomicrosensor. A
diode must be connected parallel to the relay to absorb the
reverse voltage.
OUT
Relay
5to24VDC
0V
D
The maximum detectable distance of the EE-SPZ was
determined by detecting a piece of white paper with a reflection
factor of 90%. The maximum detectable distance of each product
varies from one another by 4 to 10 mm. The background object
must not be glossy.