2702131

https://www.phoenixcontact.com/us/products/2702131
05/15/2015Page1/6
Bus coupler-IL EIP BK DI8 DO4 2TX-XC-PAC-2702131
Please be informed that the data shown in this PDF Document is generated from our Online Catalog. Please find the complete data in the user's
documentation. Our General Terms of Use for Downloads are valid
(http://phoenixcontact.com/download)
EtherNet/IP™ bus coupler, extreme conditions version, 8 inputs 24 V DC, 4 outputs 24 V DC, 500 mA, complete
with I/O connectors
Product description
The bus coupler for the EtherNet/IP™ protocol has 4 digital outputs and 8 digital inputs. This package contains all the necessary Inline plugs for
connecting the supply and the I/Os.
The Inline terminals can be labeled using pull-out labeling fields. The fields have insert cards that can be labeled individually to suit the application.
Additionally, there is the ZBFM-6... Zack marker strip for labeling the terminal points. 
Product Features
Up to 61 terminals (16 PCP devices) can be connected
8 digital inputs, 4 digital outputs onboard
EtherNet/IP™, Version 1.2
Web-based management
2 RJ45 connections
Automatic speed detection of the system bus
Diagnostic and status indicators
Can be used under extreme ambient conditions
Extended temperature range of -40°C ... +70°C (see “Tested successfully: use under extreme ambient conditions” in the data sheet)
Coated PCBs
Key commercial data
Packing unit 1 pc
Weight per Piece (excluding packing) 270.0 GRM
Custom tariff number 85389091
Country of origin Germany
Technical data
Dimensions
https://www.phoenixcontact.com/us/products/2702131
05/15/2015Page2/6
Bus coupler-IL EIP BK DI8 DO4 2TX-XC-PAC-2702131
Technical data
Dimensions
Width 80 mm
Height 119.8 mm
Depth 71.5 mm
Note on dimensions Specfications with connectors
Ambient conditions
Ambient temperature (operation) -25 °C ... 55 °C
-40 °C ... 70 °C (See “Tested successfully: use under extreme ambient
conditions” in the data sheet.)
Ambient temperature (storage/transport) -40 °C ... 85 °C
Permissible humidity (operation) 10 % ... 95 % (according to DIN EN 61131-2)
Permissible humidity (storage/transport) 10 % ... 95 % (according to DIN EN 61131-2)
Air pressure (operation) 70 kPa ... 106 kPa (up to 3000 m above sea level)
Air pressure (storage/transport) 70 kPa ... 106 kPa (up to 3000 m above sea level)
Degree of protection IP20
Connection data
Designation Inline connector
Connection method Spring-cage connection
Conductor cross section solid min. 0.08 mm²
Conductor cross section solid max. 1.5 mm²
Conductor cross section flexible min. 0.08 mm²
Conductor cross section flexible max. 1.5 mm²
Conductor cross section AWG/kcmil min. 28
Conductor cross section AWG/kcmil max 16
Stripping length 8 mm
General
Net weight 329 g
Note on weight specifications with connectors
Mounting type DIN rail
Protection class III, IEC 61140, EN 61140, VDE 0140-1
Conformance with EMC directives
Noise immunity test in accordance with EN 61000-6-2 Electrostatic
discharge (ESD) EN61000-4-2/IEC61000-4-2 Criterion B; 6 kV contact
discharge, 8 kV air discharge
Noise immunity test in accordance with EN 61000-6-2 Electromagnetic
fields EN61000-4-3/IEC61000-4-3 Criterion A; Field intensity: 10 V/m
Noise immunity test in accordance with EN 61000-6-2 Fast transients
(burst) EN61000-4-4/IEC61000-4-4 Criterion A; all interfaces 1
kVCriterion B; all interfaces 2 kV
https://www.phoenixcontact.com/us/products/2702131
05/15/2015Page3/6
Bus coupler-IL EIP BK DI8 DO4 2TX-XC-PAC-2702131
Technical data
General
Noise immunity test in accordance with EN 61000-6-2 Transient surge
voltage (surge) EN61000-4-5/IEC61000-4-5 Criterion B; supply lines DC:
0.5 kV/0.5 kV (symmetrical/asymmetrical); fieldbus cable shield 1 kV
Noise immunity test in accordance with EN 61000-6-2 Conducted
interference EN61000-4-6/IEC61000-4-6 Criterion A; Test voltage 10 V
Noise emission test as per EN 61000-6-4 EN 55011 Class A
Mechanical tests Vibration resistance in acc. with EN60068-2-6/IEC60068-2-6 5g
Shock in acc. with EN60068-2-27/IEC60068-2-27 Operation: 25g, 11 ms
duration, semi-sinusoidal shock impulse
Diagnostics messages Short-circuit / overload of the digital outputs Yes
Sensor supply failure Yes
Failure of the actuator supply Yes
System limits of the bus coupler
Designation System limits of the bus coupler
Amount of process data max. 512 Byte (per station)
Number of supported devices max. 63 (per station)
Number of local bus devices that can be connected max. 61 (on board I/Os are two devices)
Number of devices with parameter channel max. 8
Number of branch terminals with remote bus branch 0
Power supply for module electronics
Connection method Spring-cage connection
Designation
Bus coupler supply U
BC
; Communications power U
L
(7.5V) and the analog
supply U
ANA
(24 V) are generated from the bus coupler supply.
Supply voltage 24 V DC (via Inline connector)
Supply voltage range 19.2 V DC ... 30 V DC (including all tolerances, including ripple)
Current consumption
max. 0.98 A (from U
BK
)
Power loss typ. 3 W (entire device)
Communications power U
L
7.5 V DC
Current consumption 0.8 A
Power consumption typ. 1.7 W
Inline potentials
Communications power U
L
7.5 V DC ±5 %
Power supply at U
L
max. 0.8 A DC
Main circuit supply U
M
24 V DC
Supply voltage range U
M
19.2 V DC ... 30 V DC (including all tolerances, including ripple)
Power supply at U
M
max. 8 A DC (Sum of U
M
+ U
S
)
Current consumption from U
M
max. 8 A DC

2702131

Mfr. #:
Manufacturer:
Phoenix Contact
Description:
I/O Modules IL EIP BK DI8 DO4 2TX-XC-PAC
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union

Products related to this Datasheet