UHP-200A series
200W Single Output with PFC Function
4.0~4.4V
VOLTAGE ADJ. RANGE
4.7~5.3V
110~140% rated output power
SPECIFICATION
MODEL
DC VOLTAGE
RATED CURRENT
OUTPUT
LINE REGULATION
LOAD REGULATION
SETUP, RISE TIME
HOLD UP TIME (Typ.)
VOLTAGE RANGE
Note.4
FREQUENCY RANGE
POWER FACTOR (Typ.)
EFFICIENCY (Typ.)
INPUT
INRUSH CURRENT (Typ.)
LEAKAGE CURRENT
OVER TEMPERATURE
SAFETY STANDARDS
EMC EMISSION
Note.8
EMC IMMUNITY
WORKING TEMP.
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
MTBF
DIMENSION
OTHERS
NOTE
PACKING
OVERLOAD
OVER VOLTAGE
AC CURRENT (Typ.)
2000ms, 200ms/230VAC at full load, 3000ms, 200ms/115VAC at 80% load
90 ~ 264VAC 127 ~ 370VDC
Cold start 85A/230VAC
<1.0mA / 240VAC
4.6 ~ 6V
Compliance to EN55032 (CISPR32),GB9254,Class A, EN61000-3-2,-3,GB17625.1,
EAC TP TC 020
-30 ~ +70 (Refer to “OUTPUT LOAD vs TEMPERATURE")℃
20 ~ 90% RH non-condensing
-40 ~ +85 , 10 ~ 95% RH℃
±℃ ℃)0.03%/ (0 ~ 50
10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes
204K hrs min. MIL-HDBK-217F (25 )℃
PF 0.97/115VAC PF 0.95/230VAC at full load≥≥
10ms/230VAC 10ms/115VAC
88%
±2.5%
±0.5%
±4.0%
200mVp-p
4.2V
40A
UHP-200A-4.2
RIPPLE & NOISE (max.)
Note.2
VOLTAGE TOLERANCE
Note.3
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.℃
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : line regulation and load regulation.
4. Derating may be needed under low input voltages. Please check the static characteristics for more details.
5. Length of set up time is measured at cold first start. Turning ON/OFF the power supply may lead to increase of the set up time.
6. Transient response meansure shall be made with 10% load at least.
7. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on
a mm* mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives.360 360 For guidance on how to
perform these EMC tests, please refer to EMI testing of component power supplies. (as available on http://www.meanwell.com)
8. Warnning: This equipment is compliant with Class A of CISPR 32. In a residential environment may cause radio interference.
ENVIRONMENT
SAFETY &
EMC
(Note 5)
PROTECTION
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
I/P-O/P:3.0KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC/25 / 70%RH℃
5.6 ~ 7.1V
88.5%
±2.5%
±0.5%
±4.0%
200mVp-p
5V
40A
UHP-200A-5
Compliance to EN61000-4-2,3,4,5,6,8,11;EN55024, light industry level (surge 4KV),
EAC TP TC 020
SHORT CIRCUIT
Protection type : Hiccup mode, recovers automatically after fault condition is removed
167*55*26mm (L*W*H)
Protection type : Hiccup mode, recovers automatically after fault condition is removed
Protection type : Shut down O/P voltage, recovers automatically after fault condition is removed
2.4A/115VAC 1.2A/230VAC
0 ~ 40A
CURRENT RANGE
0 ~ 40A
168W
RATED POWER
(convection)
200W
0.42kg; 20pcs/ 11.4kg/0.76CUFT
47 ~ 63Hz
UL60950-1,TUV EN60950-1,CCC GB4943 approved
,
EAC TP TC 004
Protection type : Hiccup mode, recovers automatically after fault condition is removed
4.3~4.7V
5 ~ 6.4V
88%
±2.5%
±0.5%
±4.0%
200mVp-p
4.5V
40A
UHP-200A-4.5
0 ~ 40A
180W
DC OK FUNCTION
PSU Turns on:DC ok; PSU turns off:DC fail
File Name:UHP-200A-SPEC 2018-01-09