K3010P, K3010PG Series
www.vishay.com
Vishay Semiconductors
Rev. 2.2, 01-Jun-12
4
Document Number: 83504
For technical questions, contact: optocoupleranswers@vishay.com
THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT
ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000
Note
• According to DIN EN60747-5-5 (see figure 4). This optocoupler is suitable for safe electrical isolation only within the safety ratings.
Compliance with the safety ratings shall be ensured by means of suitable protective circuits.
Fig. 4 - Safety Parameter Derating Diagram Fig. 5 - Test Pulse Diagram for Sample Test according to
DIN EN60747-5-5/DIN EN60747-; IEC 60747
SAFETY AND INSULATION RATINGS
PARAMETER SYMBOL MIN. TYP. MAX. UNIT
Climatic classification (according to IEC 68 part 1) 55/100/21
Pollution degree (DIN VDE 0109) 2
Comparative tracking index CTI 175
Peak transient overvoltage V
IOTM
8000 V
peak
Peak working insulation voltage V
IORM
890 V
peak
Partial discharge test voltage (method a, V
pd
= V
IORM
x 1.875) V
pd
1669 V
peak
Isolation resistance at T
amb
= 100 °C, V
DC
= 500 V R
IO
10
11
Ω
Isolation resistance at T
amb
= 25 °C, V
DC
= 500 V R
IO
10
12
Ω
Safety rating - power P
SO
265 mW
Safety rating - input current I
SI
130 mA
Safety rating - temperature T
SI
150 °C
Clearance distance (Standard DIP-6) 7 mm
Creepage distance (Standard DIP-6) 7 mm
Clearance distance (400 mil DIP-6) 8 mm
Creepage distance (400 mil DIP-6) 8 mm
0
50
100
150
200
250
300
0 25 50 75 100 125 150
T
amb
- Ambient Temperature (°C)
P
si
(mW)
I
si
(mA)
Max. Safety Ratings
t
13930
t
1
, t
2
= 1 s to 10 s
t
3
, t
4
= 1 s
t
test
= 10 s
t
stres
= 12 s
V
IOTM
V
pd
V
IOWM
V
IORM
0
t
1
t
test
t
Tr
= 60 s
t
stres
t
3
t
4
t
2