4
Table 7. AC CHARACTERISTICS (V
DD
= 2.5 V ± 5% or V
DD
= 3.3 V ± 10%, GND = 0 V, T
A
= −40°C to +85°C) (Note 4)
Symbol
Characteristic Conditions Min. Typ. Max. Units
f
CLKOUT
Output Clock Frequency
FSEL = HIGH 125
MHz
FSEL = LOW 250
Df
Frequency Stability − NBXDPA019 (Note 5) ±50 ppm
F
NOISE
Phase−Noise Performance 100 Hz of Carrier −108/−103 dBc/Hz
f
CLKout
= 125 MHz/250 MHz
(See Figures 3 and 4)
1 kHz of Carrier −122/−11 6 dBc/Hz
10 kHz of Carrier −129/−123 dBc/Hz
100 kHz of Carrier −129/−124 dBc/Hz
1 MHz of Carrier −136/−131 dBc/Hz
10 MHz of Carrier −159/−156 dBc/Hz
t
jit
(F)
RMS Phase Jitter 12 kHz to 20 MHz 0.5 0.75 ps
t
jitter
Cycle to Cycle, RMS 1000 Cycles 4 8 ps
Cycle to Cycle, Peak−to−Peak 1000 Cycles 17 35 ps
Period, RMS 10,000 Cycles 2 4 ps
Period, Peak−to−Peak 10,000 Cycles 7 20 ps
t
OE/OD
Output Enable/Disable Time 200 ns
t
DUTY_CYCLE
Output Clock Duty Cycle
(Measured at Cross Point)
48 50 52 %
t
R
Output Rise Time (20% and 80%) 250 400 ps
t
F
Output Fall Time (80% and 20%) 250 400 ps
t
start
Start−up Time 1 5 ms
Aging
1
st
Year 3 ppm
Every Year After 1
st
1 ppm
NOTE: Device will meet the specifications after thermal equilibrium has been established when mounted in a test socket or printed circuit
board with maintained transverse airflow greater than 500 Ifpm. Electrical parameters are guaranteed only over the declared
operating temperature range. Functional operation of the device exceeding these conditions is not implied. Device specification limit
values are applied individually under normal operating conditions and not valid simultaneously.
4. Measurement taken with outputs terminated with 100 ohm across differential pair. See Figure 5.
5. Parameter guarantees 10 years of aging. Includes initial stability at 25°C, shock, vibration and first year aging.