4
AT24C128/256
0670E07/01
Pin Capacitance
(1)
Note: 1. This parameter is characterized and is not 100% tested.
DC Characteristics
(1)
Note: 1. V
IL
min and V
IH
max are reference only and are not tested
Applicable over recommended operating range from T
A
= 25°C, f = 1.0 MHz, V
CC
= +1.8V.
Symbol Test Condition Max Units Conditions
C
I/O
Input/Output Capacitance (SDA) 8 pF V
I/O
= 0V
C
IN
Input Capacitance (A
0
, A
1
, SCL) 6 pF V
IN
= 0V
Applicable over recommended operating range from: T
AI
= -40°C to +85°C, V
CC
= +1.8V to +5.5V, T
AC
= 0°C to +70°C,
V
CC
= +1.8V to +5.5V (unless otherwise noted).
Symbol Parameter Test Condition Min Typ Max Units
V
CC1
Supply Voltage 1.8 3.6 V
V
CC2
Supply Voltage 2.5 5.5 V
V
CC3
Supply Voltage 4.5 5.5 V
I
CC1
Supply Current V
CC
= 5.0V READ at 400 kHz 1.0 2.0 mA
I
CC2
Supply Current V
CC
= 5.0V WRITE at 400 kHz 2.0 3.0 mA
I
SB1
Standby Current
(1.8V option)
V
CC
= 1.8V
V
IN
= V
CC
or V
SS
0.2 µA
V
CC
= 3.6V 2.0
I
SB2
Standby Current
(2.5V option)
V
CC
= 2.5V
V
IN
= V
CC
or V
SS
0.5 µA
V
CC
= 5.5V 6.0
I
SB3
Standby Current
(5.0V option)
V
CC
= 4.5 - 5.5V V
IN
= V
CC
or V
SS
6.0 µA
I
LI
Input Leakage Current V
IN
= V
CC
or
V
SS
0.10 3.0 µA
I
LO
Output Leakage
Current
V
OUT
= V
CC
or
V
SS
0.05 3.0 µA
V
IL
Input Low Level
(1)
-0.6 V
CC
x 0.3 V
V
IH
Input High Level
(1)
V
CC
x 0.7 V
CC
+ 0.5 V
V
OL2
Output Low Level V
CC
= 3.0V I
OL
= 2.1 mA 0.4 V
V
OL1
Output Low Level V
CC
= 1.8V I
OL
= 0.15 mA 0.2 V
5
AT24C128/256
0670E07/01
AC Characteristics
Notes: 1. This parameter is characterized and is not 100% tested.
2. AC measurement conditions:
R
L
(connects to V
CC
): 1.3K (2.5V, 5V), 10K (1.8V)
Input pulse voltages: 0.3V
CC
to 0.7V
CC
Input rise and fall times: 50ns
Input and output timing reference voltages: 0.5V
CC
Applicable over recommended operating range from T
A
= -40°C to +85°C, V
CC
= +1.8V to +5.5V, CL = 100 pF (unless oth-
erwise noted). Test conditions are listed in Note 2.
Symbol Parameter
1.8-volt 2.5-volt 5.0-volt
UnitsMin Max Min Max Min Max
f
SCL
Clock Frequency, SCL 100 400 1000 kHz
t
LOW
Clock Pulse Width Low 4.7 1.3 0.6 µs
t
HIGH
Clock Pulse Width High 4.0 1.0 0.4 µs
t
AA
Clock Low to Data Out Valid 0.1 4.5 0.05 0.9 0.05 0.55 µs
t
BUF
Time the bus must be free before a new
transmission can start
(1)
4.7 1.3 0.5 µs
t
HD.STA
Start Hold Time 4.0 0.6 0.25 µs
t
SU.STA
Start Set-up Time 4.7 0.6 0.25 µs
t
HD.DAT
Data In Hold Time 0 0 0 µs
t
SU.DAT
Data In Set-up Time 200 100 100 ns
t
R
Inputs Rise Time
(1)
1.0 0.3 0.3 µs
t
F
Inputs Fall Time
(1)
300 300 100 ns
t
SU.STO
Stop Set-up Time 4.7 0.6 0.25 µs
t
DH
Data Out Hold Time 100 50 50 ns
t
WR
Write Cycle Time 20 10 10 ms
Endurance
(1)
5.0V, 25°C, Page Mode 100K 100K 100K
Write
Cycles
6
AT24C128/256
0670E07/01
Device
Operation
CLOCK and DATA TRANSITIONS: The SDA pin is normally pulled high with an external
device. Data on the SDA pin may change only during SCL low time periods (refer to Data
Validity timing diagram). Data changes during SCL high periods will indicate a start or stop
condition as defined below.
START CONDITION: A high-to-low transition of SDA with SCL high is a start condition which
must precede any other command (refer to Start and Stop Definition timing diagram).
STOP CONDITION: A low-to-high transition of SDA with SCL high is a stop condition. After a
read sequence, the stop command will place the EEPROM in a standby power mode (refer to
Start and Stop Definition timing diagram).
ACKNOWLEDGE: All addresses and data words are serially transmitted to and from the
EEPROM in 8-bit words. The EEPROM sends a zero during the ninth clock cycle to acknowl-
edge that it has received each word.
STANDBY MODE: The AT24C128/256 features a low power standby mode which is enabled:
a) upon power-up and b) after the receipt of the STOP bit and the completion of any internal
operations.
MEMORY RESET: After an interruption in protocol, power loss or system reset, any 2-wire
part can be reset by following these steps: (a) Clock up to 9 cycles, (b) look for SDA high in
each cycle while SCL is high and then (c) create a start condition as SDA is high.

AT24C256W-10SI

Mfr. #:
Manufacturer:
Description:
IC EEPROM 256K I2C 1MHZ 8SOIC
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment: