DS1869-10+

DS1869
4 of 8
DS1869 DUAL PORT CONFIGURATION (TYPICAL EXAMPLE) Figure 2B
The DS1869 is provided with two supply inputs -V and +V. The maximum voltage difference between
the two supply inputs is +8.0 volts. The minimum voltage difference is +2.7 volts. All input levels are
referenced to the negative supply input, -V. The voltage applied to any Dallastat terminal must not exceed
the negative supply voltage (-V ) by -0.5 or the positive supply voltage (+V) by +0.5 volts. The minimum
logic high level must be +2.4 volts with reference to the -V supply voltage input for +V=5V. A logic low
level with reference to the -V supply voltage has a maximum value of +0.8 volts. Dallastats exhibit a
typical wiper resistance of 400 ohms with a maximum wiper resistance of 1000 ohms. The maximum
wiper current allowed through the Dallastat is specified at 1 milliamps (see DC Electrical
Characteristics).
NONVOLATILE WIPER SETTINGS
Dallastats maintain the position of the wiper in the absence of power. This feature is provided through the
use of EEPROM type memory cell arrays. During normal operation the position of the wiper is
determined by the input multiplexer. Periodically, the multiplexer will update the EEPROM memory
cells. The manner in which an update occurs has been optimized for reliability, durability, and
performance. Additionally, the update operation is totally transparent to the user.
When power is applied to the Dallastat, the wiper setting will be the last recorded in the EEPROM
memory cells. If the Dallastat setting is changed after power is applied, the new value will be stored after
a delay of 2 seconds. The initial storage of a new value after power-up occurs when the first change is
made, regardless of when this change is made.
After the initial change on power-up all subsequent changes of the wiper position will be recorded only if
the 4
th
LSB (out of a 6-bit total for 64 positions) is being changed. Thus any change greater than 12.5% of
the total resistance range will trigger one EEPROM write cycle.
Changes or storage to the EEPROM memory cells must allow for a 2-second delay to guarantee that
updates will occur. The EEPROM memory cells are specified to accept greater that 50,000 writes before a
wear-out condition. If the EEPROM memory cells do reach a wear-out condition, the Dallastat will still
function properly while power is applied. However, on power-up the device’s wiper position will be that
of the position last recorded before memory cell wear-out.
DS1869
5 of 8
FLOWCHART: ONE-BUTTON OPERATION
AND ELECTRICAL CONTROL Figure 3
CONTACT OPEN AND CONTACT CLOSURE TIMING IS 1 SECOND ± 15%
DS1869
6 of 8
FLOWCHART: TWO-BUTTON OPERATION Figure 4
CONTACT OPEN AND CONTACT CLOSURE TIMING IS 1 SECOND ± 15%

DS1869-10+

Mfr. #:
Manufacturer:
Maxim Integrated
Description:
Digital Potentiometer ICs 3V Dallastat Digital Rheostat
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union