ABSOLUTE MAXIMUM RATINGS*
Voltage on Any Pin Relative to -V -V -0.5V +8.0V
Operating Temperature -40°C to +85°C
Storage Temperature -55°C to +125°C
Soldering Temperature 260°C for 10 seconds
* This is a stress rating only and functional operation of the device at these or any other conditions
above those indicated in the operation sections of this specification is not implied. Exposure to
absolute maximum rating conditions for extended periods of time may affect reliability.
RECOMMENDED DC OPERATING CONDITIONS (-40°C to +85°C)
PARAMETER SYMBOL MIN TYP MAX UNITS NOTES
+ Supply Voltage +V -V + 2.7 -V + 8.0 V
- Supply Voltage -V +V - 8.0 +V - 2.7 V
Resistor Inputs R
H
,R
W
,R
L
-V - 0.5 +V + 0.5 V
Logic Input 1 V
IH
+2.4 V 1, 2, 10
Logic Input 0 V
IL
+0.8 V 1, 2, 10
Wiper Current I
W
1mA5
DC ELECTRICAL CHARACTERISTICS
(-40°C to +85°C; -V to +V = 2.7V to 8.0V)
PARAMETER SYMBOL MIN TYP MAX UNITS NOTES
End to End Resistor Tolerance -20 20 % 11
+, - Supply Current I
CC1
12mA3
Supply Current, Idle State
At 3.3V
At 8.0V
I
CC2
2
10
µA
9
Wiper Resistance R
W
400 1000
Temperature Coefficient 750
ppm/°C
AC ELECTRICAL CHARACTERISTICS
(-40°C to +85°C; -V to +V = 2.7V to 8.0V)
PARAMETER SYMBOL MIN TYP MAX UNITS NOTES
Input Pulse Width (D-input) t
PW
1DC
µs
1, 7, 8
Contact Pulse Width
(UC, DC inputs)
t
CPW
1 DC ms 1, 7, 8
Capacitance C
IN
510pF6
Repetitive Input Pulse High Time t
HPW
1 DC ms 1, 7, 8
Continuous Input Pulse t
CCP
1 DC s 1, 7, 8
DS1869
8 of 8
TIMING DIAGRAMS Figure 5
NOTES:
1. All inputs; UC, DC, and D are internally pulled up with a typical resistance of 100 k.
2. Input logic levels are referenced to -V.
3. I
CC
is the internal current that flows between -V and +V.
4. Input leakage applies to contact inputs UC and DC and the digital input (D).
5. Wiper current is the maximum current which can flow through the wipers.
6. Capacitance values apply at 25°C.
7. Input pulse width is the minimum time required for an input to cause an increment or decrement. If
the UC, DC, or D input is held active for longer than 1 second, subsequent increments or decrements
will occur on 100 ms intervals until the inputs UC, DC, and/or D is released to V
IH
.
8. Repetitive pulsed inputs on UC, DC, or D will be recognized as long as the pulse repetition occurs
within 1 second of each other. Pulses occurring faster than 1 ms apart may not be recognized as
individual inputs but can be interpreted a constant input. Tolerance for pulse timing is ±15% on
minimum inputs.
9. Idle state supply current is measured with no pushbutton pressed and with the wiper R
W
tied to a
CMOS load.
10. For +V referenced to -V = 5V.