10
FN8161.5
April 9, 2014
Submit Document Feedback
Absolute Maximum Ratings Thermal Information
Temperature Under Bias . . . . . . . . . . . . . . . . . . . . .-65°C to +135°C
Voltage on SCL, SDA, or Any Address Input
with Respect to VSS. . . . . . . . . . . . . . . . . . . . . . . . . . . -1V to +7V
Voltage on V+ (referenced to V
SS
) (Note 8) . . . . . . . . . . . . . . . .10V
Voltage on V- (referenced to V
SS
) (Note 8) . . . . . . . . . . . . . . . . -10V
(V+) – (V-) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12V
Any Voltage on R
H
/R
L
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .V+
Any Voltage on R
L
/R
H
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V-
I
W
(10s) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ±6mA
Supply Voltage (VCC) Limits (Note 8)
X9118 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5V ±10%
X9118-2.7 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.7V to 5.5V
Thermal Resistance (Typical, Note 3, 4) . θ
JA
(°C/W) θ
JC
(°C/W)
14 Ld TSSOP . . . . . . . . . . . . . . . . . . . . 92 25
Storage Temperature . . . . . . . . . . . . . . . . . . . . . . . .-65°C to +150°C
Pb-Free Reflow Profile. . . . . . . . . . . . . . . . . . . . . . . . .see link below
http://www.intersil.com/pbfree/Pb-FreeReflow.asp
Recommended Operating Conditions
Commercial . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0°C to +70°C
Industrial . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .-40°C to +85°C
Power Rating (each pot) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50mW
Wiper current (max) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ±3mA
CAUTION: Do not operate at or near the maximum ratings listed for extended periods of time. Exposure to such conditions may adversely impact product
reliability and result in failures not covered by warranty.
NOTES:
3. θ
JA
is measured with the component mounted on a high effective thermal conductivity test board in free air. See Tech Brief TB379 for details.
4. For θ
JC
, the “case temp” location is taken at the package top center.
Analog Specifications T
A
= +25°C, unless otherwise noted. Boldface limits apply across the operating temperature range , -40°C to +85°C.
SYMBOL PARAMETER TEST CONDITIONS
MIN
(Note 10) TYP
MAX
(Note 10) UNITS
R
TOTAL
End to End Resistance 100 kΩ
End to End Resistance Tolerance ±20 %
R
W
Wiper Resistance I
W
= (V
RH
- V
RL
)/R
TOTAL
, V
CC
= 3V, V
RL
= -3V 150 500 Ω
R
W
Wiper Resistance I
W
= (V
RH
- V
RL
)/R
TOTAL
, V
CC
= 5V, V
RL
= 0V 40 100 Ω
Vv+ Voltage on V+ Pin X9118 (Note 8) +4.5 +5.5 V
X9118-2.7 (Note 8) +2.7 +5.5 V
Vv- Voltage on V- Pin X9118 -5.5 -4.5 V
X9118-2.7 -5.5 -2.7 V
V
TERM
Voltage on any R
H
or R
L
Pin V
SS
= 0V V- V+ V
Noise Ref: 1kHz -120 dBV
Resolution 0.1 %
Absolute Linearity (Note 5) R
w(n)(actual)
– R
w(n)(expected)
, where n = 1 to
1023
±1.5 MI
(Note 7)
Relative Linearity (Note 6) R
w(m + 1)
– [R
w(m)
+ MI], where m = 1 to 1023 ±1.5 MI
(Note 7)
Temperature Coefficient of R
TOTAL
±300 ppm/°C
Ratiometric Temperature
Coefficient
Wiper at middle point ±20 ppm/°C
C
H
/C
L
/C
W
Potentiometer Capacitances See Macro model 10/10
/25
pF
NOTES:
5. Absolute linearity is utilized to determine actual wiper voltage versus expected voltage as determined by wiper position when used as a
potentiometer.
6. Relative linearity is utilized to determine the actual change in voltage between two successive tap positions when used as a
potentiometer. It is a measure of the error in step size.
7. MI = R
TOT
/1023 or (R
H
– R
L
)/1023, single pot.
8. V
CC
, V+, V- must reach their final values within 1ms of each other.
9. n = 0, 1, 2, …,1023; m = 0, 1, 2, …, 1022.
X9118
11
FN8161.5
April 9, 2014
Submit Document Feedback
DC Operating Specifications T
A
= +25°C, unless otherwise noted. Boldface limits apply across the operating temperature range ,
-40°C to +85°C.
SYMBOL PARAMETER TEST CONDITIONS
MIN
(Note 10) TYP
MAX
(Note 10) UNITS
I
CC1
V
CC
Supply Current (Active) f
SCL
= 400kHz; V
CC
= +5.5V; SDA = Open;
(for 2-wire, Active, Read and Volatile Write States only)
3 mA
I
CC2
V
CC
Supply Current (Nonvolatile Write) f
SCL
= 400kHz; V
CC
= +5.5V; SDA = Open;
(for 2-wire, Active, Non-volatile Write State only)
7 mA
I
SB
V
CC
Current (Standby) V
CC
= +5.5V; V
IN
= V
SS
or V
CC
; SDA = V
CC
;
(for 2-wire, Standby State only)
15 μA
I
LI
Input Leakage Current V
IN
= V
SS
to V
CC
10 μA
I
LO
Output Leakage Current V
OUT
= V
SS
to V
CC
10 μA
V
IH
Input HIGH Voltage V
CC
x 0.7 V
CC
+ 1 V
V
IL
Input LOW Voltage -1 V
CC
x 0.3 V
V
OL
Output LOW Voltage I
OL
= 3mA 0.4 V
NOTE:
10. Parameters with MIN and/or MAX limits are 100% tested at +25°C, unless otherwise specified. Temperature limits established by characterization
and are not production tested.
Endurance and Data Retention
PARAMETER MIN UNITS
Minimum Endurance 100,000 Data changes per bit per register
Data Retention 100 years
Capacitance
SYMBOL TEST TYP UNITS TEST CONDITIONS
C
IN/OUT
(Note 11)
Input/Output Capacitance (SI) 8 pF V
OUT
= 0V
C
IN
(Note 11) Input Capacitance (SCL, WP, A1 and A0) 6 pF V
IN
= 0V
Power-Up Timing
SYMBOL PARAMETER MIN MAX UNITS
t
r
V
CC
(Note 11)
V
CC
Power-up Rate 0.2 50 V/ms
t
PUR
(Note 12) Power-up to Initiation of Read Operation 1 ms
t
PUW
(Note 12) Power-up to Initiation of Write Operation 50 ms
NOTES:
11. This parameter is not 100% tested.
12. t
PUR
and t
PUW
are the delays required from the time the (last) power supply (V
CC
-) is stable until the specific instruction can be issued. These
parameters are periodically sampled and not 100% tested.
AC Test Conditions
Input Pulse Levels V
CC
x 0.1 to V
CC
x 0.9
Input Rise and Fall Times 10ns
Input and Output Timing Level V
CC
x 0.5
X9118
12
FN8161.5
April 9, 2014
Submit Document Feedback
Equivalent A.C. Load Circuit
R
H
10pF
C
L
C
L
R
W
R
TOTAL
C
W
25pF
10pF
R
L
SPICE MACROMODEL
5V
1533
100pF
SDA OUTPUT
3V
867
100pF
SDA OUTPUT
AC Timing High-Voltage Write Cycle Timing
SYMBOL PARAMETER MIN MAX UNITS
f
SCL
Clock Frequency 400 kHz
t
CYC
Clock Cycle Time 2500 ns
t
HIGH
Clock High-Time 600 ns
t
LOW
Clock Low-Time 1300 ns
t
SU:STA
Start Setup Time 600 ns
t
HD:STA
Start Hold Time 600 ns
t
SU:STO
Stop Setup Time 600 ns
t
SU:DAT
SDA Data Input Setup Time 100 ns
t
HD:DAT
SDA Data Input Hold Time 30 ns
t
R
SCL and SDA Rise Time 300 ns
t
F
SCL and SDA Fall Time 300 ns
t
AA
SCL Low to SDA Data Output Valid Time 250 ns
t
DH
SDA Data Output Hold Time 0 ns
t
I
Noise Suppression Time Constant at SCL and SDA inputs 50 ns
t
BUF
Bus Free Time (Prior to Any Transmission) 1300 ns
t
SU:WPA
A0, A1 Setup Time 0 ns
t
HD:WPA
A0, A1 Hold Time 0ns
High-Voltage Write Cycle Timing
SYMBOL PARAMETER TYP MAX UNITS
t
WR
High-Voltage Write Cycle Time (store instructions) 5 10 ms
XDCP Timing
SYMBOL PARAMETER TYP UNITS
t
WRPO
Wiper Response Time After the Third (last) Power Supply is Stable 8 µs
t
WRL
Wiper Response Time After Instruction Issued (all load instructions) 8 µs