E3Z
E3Z
11
Sensor I/O Connectors
Straight
XS3F-M421-402-A
(L=2 m)
XS3F-M421-405-A (L=5 m)
L-shaped
XS3F-M422-402-A (L=2 m)
XS3F-M422-405-A (L=5 m)
4 dia.
4 dia.
9
dia.
Precautions
Be
sure to abide by the following precautions for the safe operation
of
the Sensor
.
Wiring
Power Supply Voltage
Make sure that the power supply to the Sensor is within the rated
voltage
range and do not apply 100 V
AC or more if the Sensor is a
DC
model, or otherwise the Sensor may explode or burn.
Load Short-circuiting
Do not short-circuit the load, otherwise the Sensor may be dam-
aged.
Wiring
Mistakes
Do
not make
mistakes in wiring, such as mistakes in polarity
, other
-
wise
the Sensor may be damaged.
Connection without Load
Do
not connect power supply to the Sensor with no load connected,
otherwise
the internal elements may explode or burn.
Operating Environment
Do
not use the Sensor in locations
with explosive or flammable gas.
Correct Use
Settings
Power
Reset T
ime
The Sensor is ready to operate 100 ms after the Sensor is turned
ON. If the load and Sensor are connected to independent power
supplies
respectively
, be sure to turn ON the
Sensor before turning
the
load ON.
Connections
M8 Metal Connector
• Be sure to connect or disconnect the metal connector after
turning
OFF the Sensor
.
• Hold the connector cover to connect or disconnect the metal
connector.
• Secure the connector cover by hand. Do not use any pliers,
otherwise
the connector may be damaged.
• The
proper tightening torque range is between 0.3 and 0.4 N
S
m.
Be sure to tighten the connector securely, otherwise the
specified degree of protection may not be maintained or the
connector
may be disconnected due to vibration.
Mounting
Sensor Mounting
Use M3 screws to mount the sensor and tighten each screw to a
maximum
torque of 0.53 N
S
m.
E3Z-jjj E39-L104 Mounting Bracket
(sold separately)