STTH16L06C Characteristics
Doc ID 10760 Rev 2 3/10
Table 5. Dynamic electrical characteristics
Symbol Parameter
Test conditions
Min. Typ Max. Unit
t
rr
Reverse recovery time T
j
= 25 °C
I
F
= 0.5 A, I
rr
= 0.25 A, I
R
= 1 A 35
ns
I
F
= 1 A, dI
F
/dt = 50 A/µs,
V
R
= 30 V
40 55
I
RM
Reverse recovery current T
j
= 125 °C
I
F
= 8 A, dI
F
/dt = 100 A/µs,
V
R
= 400 V
4.5 6.5 A
t
fr
Forward recovery time
T
j
= 25 °C
I
F
= 8 A dI
F
/dt = 100 A/µs
V
FR
= 1.1 x V
Fmax
200 ns
V
FP
Forward recovery voltage 3.5 V
Figure 1. Conduction losses versus average
current
Figure 2. Forward voltage drop versus
forward current
Figure 3. Relative variation of thermal
impedance junction to case versus
pulse duration (TO-220AB, D
2
PAK)
Figure 4. Relative variation of thermal
impedance junction to case versus
pulse duration (TO-220FPAB)
0
5
10
15
0246810
P(W)
T
δ
=tp/T
tp
δ = 0.05
δ = 1
I (A)
F(AV)
δ = 0.1
δ = 0.2
δ = 0.5
0
10
20
30
40
50
60
70
80
90
100
0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5
I (A)
FM
T =150°C
(typical values)
j
T =25°C
(maximum values)
j
T =150°C
(maximum values)
j
V (V)
FM
0.0
0.1
0.2
0.3
0.4
0.5
0.6
0.7
0.8
0.9
1.0
1.E-03 1.E-02 1.E-01 1.E+00
Z/R
th(j-c) th(j-c)
t (s)
p
Single pulse
0.0
0.1
0.2
0.3
0.4
0.5
0.6
0.7
0.8
0.9
1.0
1.E-03 1.E-02 1.E-01 1.E+00 1.E+01
Z/R
th(j-c) th(j-c)
t (s)
p