2938714

MINI POWER provides:
Extra narrow
widths of 22.5 and 45 mm (0.886 and
1.772 in.)
Global use
due to a wide range input
A high level of operational safety
in complex global
networks
Reliable start up
of heavy loads due to POWER
BOOST
The reliability of a power supply determines the
availability of individual components in a system and
whether complex systems can function safely.
The globalization of markets increases the demands
placed on the power supply. A wide range input and a
high level of availability are required. These
requirements are met by MINI POWER.
1. Brief Description
MINI POWER is the extra narrow power supply,
which is available in widths of 22.5 and 45 mm (0.886
and 1.772 in.).
In addition to a 24 V version with output currents of
0.65 A and 2 A, special voltages are also available with
5 V/3 A and +/- 15 V/1 A.
The POWER BOOST - a power reserve of up to
100% - ensures a reliable start of difcult loads.
The high level of operational safety is also ensured in
complex global networks. MINI POWER also operates
in applications where static voltage dips, transient
power supply failures or phase failure are common.
Large capacitors ensure mains buffering of more
than 20 ms at full load.
2. Area of Application
MINI POWER can be used globally due to the
consistent conversion of a wide range input.
In this way, your entire system can be tested at any
production location in the world and can be delivered to
any location in the world without faulty switching of the
input voltage. This reduces storage costs and logistical
effort.
An international approval package including
UL 60950 for IT equipment and UL 508 for industrial
control equipment enables the device to be used
globally.
Power Supply, Primary Switch Mode, Narrow Design
MINI-PS-100-240AC/5DC/3
Headquarters: © Phoenix Contact GmbH & Co. KG • Flachsmarktstraße 8 • 32825 Blomberg • Germany
Phone +49 - 52 35 - 30 0 • Fax +49 - 52 35 - 34 12 00 • www.phoenixcontact.com
Local contact: www.phoenixcontact.com/salesnetwork
PHOENIX CONTACT page 2 of 8
solid exible torque
[mm
2
] AWG [Nm]
Input 0.2 - 2.5 0.2 - 2.5 24 - 14 0.5 - 0.6
Output 0.2 - 2.5 0.2 - 2.5 24 - 14 0.5 - 0.6
Description
Power Supply
,
primary switch mode, narrow design
Technical Data
Input Data
1
Nominal input voltage
Input voltage range
Frequency
Current consumption (for nominal values)
Inrush current limiting/I
2
t (+25°C [+77˚F])
Mains buffering for a nominal load (typical)
Switch-on time after applying the AC supply voltage
Transient surge protection
Input fuse, internal
Recommended fuse
Output Data
2
Nominal output voltage U
N
/tolerance
Setting range for the output voltage
Output current during convection cooling and nominal values
POWER BOOST I
BOOST
(t = 2, minutes [typical])
Nominal output current I
N
-25°C to +60°C (-13˚F to +140˚F)
Derating
Short-circuit current limit
Startup of capacitive loads
System deviation on: Load change static 10 - 90%
Load change dynamic 10 - 90%
Input voltage change ±10%
Maximum power loss No load/nominal load
Level of efciency (typical)
Response time U
OUT
(10% - 90%)
Residual ripple/switching peaks (20 MHz)
Can be connected in parallel
Internal surge protection
Resistance to return supply
Signal Output Data
LED (U
out
> 4 V DC
=
LED permanently on)
MINI-PS-100-240AC/5DC/3
1 AC
U u
Type Order No.
Pcs
.
Pkt.
MINI-PS-100-240AC/5DC/3 29 38 71 4
1
100 - 240 V AC (wide range input)
85 - 264 V AC (0.4-0.2 A) 90 - 350 V DC (0.4-0.2 A)
45 - 65 Hz 0 Hz
0.2 A (120 V AC) - 0.4 A (230 V AC), approximately
< 25 A/< 1.5 A
2
s, typical
> 20 ms (120 V AC)/> 100 ms (230 V AC)
< 1 s
Varistor
2 AT (device protection)
Circuit breaker 10 A or 16 A
Characteristic B (EN 60 898)
5 V DC/±1%
4.5 - 5.5 V DC
Up to 6 A (U
out
= 5 V DC)
3 A (U
out
= 5 V DC)
From +60°C (+140˚F), 5% per Kelvin
I
BOOST
6 A, approximately
Unlimited
< 1%, typical
< 3%, typical
< 0.1%, typical
1.7 W/5 W
> 73% (for 230 V AC and nominal values)
< 100 ms, typical
< 100 mV
pp
(for nominal values)
To increase redundancy and power
Ye s, limited to 20 V DC, approximately
6 V DC
Green LED
99
22.5
114.5
L (+)
N (–)
NC
NC
Power Supply, Primary Switch Mode, Narrow Design – MINI-PS-100-240AC/5DC/3
3. Technical Data
8 mm (0.31 in.)
PHOENIX CONTACT page 3 of 8
Power Supply, Primary Switch Mode, Narrow Design – MINI-PS-100-240AC/5DC/3
General Data
Isolation voltage: Input/output
Approval package
Safety transformers for switched-mode power supplies
Electrical safety
(of IT equipment)
Industrial control equipment
Equipping high voltage installations
with electronic equipment
Safety extra-low voltage
Safe isolation
Protection against electric shock
Protection against dangerous shock currents,
basic requirements for safe isolation
in electrical equipment
Limitation of harmonic line currents
Mounting position
Can be mounted with spacing - Vertical
- Horizontal
Degree of protection
Class of protection
MTBF
Housing version
Dimensions (W x H x D)
Weight
Climatic Data
Ambient temperature Operation
Storage
Humidity
Vibration according to IEC 68-2-6
Shock according to IEC 68-2-27
Degree of pollution
Climatic category
cc
cc
Conforms to the EMC Directive 89/336/EEC and the
Low Voltage Directive 73/23/EEC
EMC (Electromagnetic Compatibility)
Noise Immunity According to EN 61000-6-2:
Electrostatic discharge
(ESD)
EN 61000-4-2
3)
Housing
Contact discharge:
Air discharge:
Electromagnetic
HF eld
EN 61000-4-3
2)
Housing
Frequency:
Field strength:
Fast transients
(burst)
EN 61000-4-4
3)
Input:
Output:
Surge current loads EN 61000-4-5
3)
Input:
Output:
Conducted
interference
EN 61000-4-6
2)
I/O:
Frequency:
U
0
:
Voltage dips EN 61000-4-11
3)
Input:
Simulation of
radiophone
EN 50204 Frequency:
Field strength:
Noise Emission According to EN 50081-2:
Radio interference EN 55011
Radio interference EN 55011
EN 55011 corresponds to CISPR11/EN 55022 corresponds to
CISPR22
EN 61000 corresponds to IEC 1000
2)
Criterion A: Normal operating characteristics within the specied
limits.
3)
Criterion B: Temporary adverse effects on the operating
characteristics that the device corrects
4 kV AC (type test)/3 kV AC (routine test)
EN 61 558-2-17
EN 60950/VDE 0805
UL/C-UL Recognized UL 60 950
u
1)
UL/C-UL Listed UL 508
1)
EN 50 178/VDE 0160 (Surge Voltage Category III)
PELV (EN 50 178)
SELV (EN 60 950)
VDE 0100-410
DIN 57 100-410
DIN VDE 0106-101
According to EN 61000-3-2
On horizontal NS 35 DIN rail according to EN 50022
8 cm (0.31 in.)
0 cm
IP 20
ΙΙ
, (in closed control cabinets)
> 500 000 h according to IEC 1709 (SN 29 500)
Polyamide PA, color green
(22.5 x 99 x 114.5 mm [0.886 x 3.898 x 4.508 in.])
0.17 kg, approximately
-25°C to +70°C (-13˚F to +158˚F) (> +60°C [+140˚F] derating)
-40°C to +85°C (-40˚F to +185˚F)
up to 95% at +25°C (+77˚F), no condensation
< 15 Hz, amplitude ±2.5 mm/15 Hz - 150 Hz, 2.3 g
30 g all space directions
2 (according to EN 50 178)
3K3 (according to EN 60 721)
1)
UL approval for AC input voltage and ambient temperature up to
+60°C (+140°F)
Requirements
EN 61 000-6-2 MINI-PS-100-240AC/5DC/3
4 kV
8 kV
Level 3
8 kV
8 kV
80 - 1000 MHz
10 V/m
Level 3
80 - 1000 MHz/1.4 - 2.0 GHz
10 V/m
2 kV asymmetrical
5)
2 kV asymmetrical
5)
4 kV (Level 4)
2 kV (Level 3)
2 kV asymmetrical
5)
1 kV symmetrical
4)
0.5 kV asymmetrical
5)
0.5 kV symmetrical
4)
2 kV (Level 3)
1 kV (Level 3)
0.5 kV (Level 1)
0.5 kV (Level 1)
asymmetrical
5)
0.15 - 80 MHz
10 V
Level 3
0.15 - 80 MHz
10 V
30% reduction of the input
voltage for 0.5 periods
See input data:
Mains buffering
> 20 ms
Not required 900 MHz/1800 MHz
20 V/m
Class A
6)
EN 55011 (EN 55022) Class B
7)
Class A
6)
EN 55011 (EN 55022) Class B
7)
4)
symmetrical: Cable to cable
5)
asymmetrical: Cable to ground
6)
Class A: Industrial application
7)
Class B: Industrial and domestic applications
U
LISTED

2938714

Mfr. #:
Manufacturer:
Phoenix Contact
Description:
DIN Rail Power Supplies 100-240AC 5DC 3A
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union

Products related to this Datasheet