7
Test Circuit and Timing Diagrams
FIGURE 2A. TYPICAL TEST CIRCUIT FIGURE 2B. TEST CIRCUIT FOR 600s TIME-OUT
FIGURE 3A. OV TO GATE TIMING
FIGURE 3B. UV TO GATE TIMING
FIGURE 3. OV AND UV TO GATE TIMING
FIGURE 4A. DRAIN TO PWRGD
TIMING (ISL6141) FIGURE 4B. DRAIN TO PWRGD TIMING (ISL6151)
FIGURE 4. DRAIN TO PWRGD
/PWRGD TIMING
FIGURE 5A. GATE TO PWRGD
(ISL6141)
FIGURE 5B. GATE TO PWRGD (ISL6151)
FIGURE 5. GATE TO PWRGD
/PWRGD TIMING
OV
V
EE
5
7
6
4
3
2
GATE
DRAIN
UV
SENSE
PWRGD
1
V
DD
8
5V
V
OV
V
UV
48V
V
DRAIN
V
SENSE
ISL6141
ISL6151
R = 5K
+
-
.
OV
V
EE
5
7
6
4
3
2
GATE
DRAIN
UV
SENSE
PWRGD
1
V
DD
8
5V
V
OV
V
UV
48V
V
DRAIN
ISL6141
ISL6151
R = 5K
+
-
0.1K
0.9K
9.0K
GATE
t
PHLOV
t
PLHOV
0V
2V
1V
1.255V 1.230V
1V
0V
13.6V
OV Pin
GATE
t
PHLUV
t
PLHUV
2V
0V
1V
1.120V 1.255V
1V
13.6V
0V
UV Pin
t
PHLDL
DRAIN
PWRGD
1.3V
1.0V
V
EE
V
PG
PWRGD
t
PHLDL
1.3V
1.0V
DRAIN
V
EE
V
PG
t
PHLGH
2.5V
1.0V
GATE
PWRGD
V
GATE
- V
GATE
= 0V
V
GH
t
PLHGH
GATE
PWRGD
2.5V
1.0V
V
PWRGD
- V
DRAIN
= 0V
V
GATE
- V
GATE
= 0V
V
GH
ISL6141, ISL6151
8
FIGURE 6. SENSE TO GATE TIMING FIGURE 7. SENSE TO GATE (Hard Fault) TIMING
FIGURE 8. CURRENT LIMIT TO GATE TIMING
Test Circuit and Timing Diagrams (Continued)
SENSE
GATE
t
PHLSENSE
~4V (depends on FET threshold)
50mV
SENSE
GATE
t
PHLHF
V
EE
210mV
13.6V
0V
t
PHLCB
UV
1.0V
1.0V
GATE
Typical Performance Curves
FIGURE 9. SUPPLY CURRENT VS. SUPPLY VOLTAGE (25
o
C) FIGURE 10. SUPPLY CURRENT VS. TEMPERATURE, V
DD
= 48V
0
0.5
1
1.5
2
2.5
3
3.5
4
4.5
10 20 30 40 50 60 70 80 90 100
Supply Voltage (VDD)
IDD (mA)
1.95
2
2.05
2.1
2.15
2.2
2.25
2.3
-40-20 0 20406080100
Temperature (C)
IDD (mA)
ISL6141, ISL6151
9
FIGURE 11. SUPPLY CURRENT VS TEMPERATURE, V
DD
= 80V FIGURE 12. GATE VOLTAGE VS SUPPLY VOLTAGE (25
o
C)
FIGURE 13. GATE VOLTAGE VS TEMPERATURE, V
DD
= 48V FIGURE 14. GATE VOLTAGE VS TEMPERATURE, V
DD
= 80V
FIGURE 15. GATE VOLTAGE VS TEMPERATURE, V
DD
= 20V
FIGURE 16. GATE PULL-UP CURRENT VS TEMPERATURE
Typical Performance Curves (Continued)
2.1
2.15
2.2
2.25
2.3
2.35
2.4
2.45
-40-20 0 20406080100
Temperature (C)
IDD (mA)
0
2
4
6
8
10
12
14
16
10 20 30 40 50 60 70 80 100
Supply Voltage (VDD)
Gate Voltage (V)
13.4
13.5
13.6
13.7
13.8
13.9
14
-40 -20 0 20 40 60 80 100
Temperature (C)
Gate Voltage (V)
13.4
13.5
13.6
13.7
13.8
13.9
14
-40-200 20406080100
Temperature (C)
Gate Voltage (V)
41
42
43
44
45
46
47
48
49
50
-40 -20 0 20 40 60 80 100
Temperature (C)
Gate Current (uA)
ISL6141, ISL6151

ISL6151CBZA-T

Mfr. #:
Manufacturer:
Renesas / Intersil
Description:
Hot Swap Voltage Controllers W/ANNEAL 8LD 0+70 HISIDE HOTPLUG CONTR
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment: