52
Dimensions are in inches and millimeters unless otherwise specified. Values in italics
are metric equivalents. Dimensions are shown for reference purposes only.
Specifications subject to change.
Corcom Product Guide
Catalog: 1654001
Issue Date: 06.2011
For email, phone or live chat, please go to
te.com/help
corcom.com
General Purpose RFI Power Line Filters (continued)
K Series
Part No.
ABCDE
1VK1, 1EK1,
2VK1, 2EK1
1VK3, 1EK3,
2VK3, 2EK3
3VK1, 3EK1,
5VK1, 5EK1
3VK3, 3EK3,
5VK5, 5EK3
3VK7/7M,
3EK7/7M
5VK7/7M,
5EK7/7M
10VK1,
10EK1
10VK3,
10EK3
10VK6
10VK7/7M,
10EK7/7M
20VK1,
20EK1
20VK6
20VK7
30VK6,
30VK6C
40VK6,
40VK6C
60VK6
Case Dimensions
Recommended Panel Cutouts
5.96
1.575
40.01
.157
3.98
.910
23.1
Dia.
1.295
32.89
R
K7 & K7M Cutout (3, 5, 10A)
.062
1.60
4.0
Dia.
R
1.46
37.1
1.145
29.1
D
20VK7 Cutout
Performance Data
Typical Insertion Loss
1 & 3EK
0.1 1 10 30
Frequency in MHz
db
100
90
80
70
60
50
40
30
20
10
0
2 & 10EK
0.1 1 10 30
Frequency in MHz
db
100
90
80
70
60
50
40
30
20
10
0
Measured in closed 50 Ohm system
5EK
0.1 1 10 30
Frequency in MHz
db
100
90
80
70
60
50
40
30
20
10
0
20EK
0.1 1 10 30
Frequency in MHz
db
100
90
80
70
60
50
40
30
20
10
0