MKP1847H AC Filtering
www.vishay.com
Vishay Roederstein
Revision: 16-Mar-17
10
Document Number: 26067
For technical questions, contact: dc-film@vishay.com
THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT
ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000
APPLICATION NOTES AND LIMITING CONDITIONS
These capacitors are not suitable for mains applications as across-the-line capacitors without additional protection.
These mains applications are strictly regulated in safety standards and therefore electromagnetic interference suppression
capacitors conforming the standards must be used.
To select the capacitor for a certain application, the following conditions must be checked:
1. The peak voltage (U
p+
) shall not be greater than
2. The peak-to-peak ripple voltage (U
pp
) shall not be greater than (for U
RMS
consult graph “Maximum RMS
Voltage as Function of Frequency)
3. The voltage pulse slope (dU/dt) shall not exceed the rated pulse slope at the DC voltage rating.
If the pulse voltage is lower than the rated DC voltage, the rated voltage pulse slope may be multiplied by U
NDC
and divided
by the applied voltage.
T is the pulse duration
4. The maximum component surface temperature must be lower than 105 °C and maximum temperature rise between case
and free air ambient shall be lower than 15 °C.
INSPECTION REQUIREMENTS
SUB-CLAUSE NUMBER AND TEST CONDITIONS PERFORMANCE REQUIREMENTS
ROUTINE TEST - FINAL INSPECTION
5.14.2-1
External inspection, visual examination
Legible marking as specified
5.14.2-2
Dimensions
See specification drawing
5.3-1
Capacitance
1 kHz at room temperature See specific reference data
5.3-2
tan
10 kHz at room temperature See specific reference data
5.5.1-2
Voltage test between terminals
1.5 x U
NDC
at T
amb
Duration: 2 s
No visible damage or puncture
No flashover
5.7
Insulation resistance
Measuring voltage 500 V at room
temperature
Duration: 1 min
See specific reference data
TYPE TESTS
5.14.2
External inspection
Check for finish, marking, and overall
dimensions
Legible marking and finish as specified
Dimensions: see specification drawing
5.14.0
Initial measurements
Capacitance at 1 kHz
tan at 10 kHz
5.14.1-1/4 Tensile Ua1
Robustness of terminations
IEC 60068-2-21
Wire diameter Section Load
d 0.80 mm S 0.5 mm
2
10 N
(± 10 %)
d 1.25 mm S 1.2 mm
2
20 N
(± 10 %)
Duration: 10 s ± 1 s
Bending, Ub method 1
Wire diameter Section modulus Load
d 0.80 mm Z
x
0.05 mm
3
5 N
(10 %)
d 1.25 mm Z
x
0.019 mm
3
10 N
(± 10 %)
4 x 90°, duration: 2 s to 3 s/bend
5.14.1-6
Resistance to soldering heat
IEC 60068-2-20
No pre-drying, method 1A
Solder bath: 280 °C ± 5 °C
Duration: 10 s ± 1 s
5.14.4
Final measurements
Capacitance
tan
|C/C| 0.5 %
Increase of tan 0.0050
compared to the values measured in 5.14.0
2 x
dU
dt
-------
2
x dt < U
NDC
x
dU
dt
-------
rated
0
T