Data Sheet ADuM2200/ADuM2201
Rev. G | Page 7 of 17
PACKAGE CHARACTERISTICS
Table 13.
Parameter Symbol Min Typ Max Unit Test Conditions/Comments
Resistance (Input-to-Output)
1
Capacitance (Input-to-Output)
C
2 pF f = 1 MHz
Input Capacitance
C
4 pF
IC Junction-to-Ambient Thermal Resistance θ
45 °C/W
1
This device is considered a 2-terminal device: Pin 1 through Pin 8 are shorted together, and Pin 9 through Pin 16 are shorted together.
2
Input capacitance is from any input data pin to ground.
REGULATORY INFORMATION
The ADuM2200/ADuM2201 are approved by the organizations listed in Table 14. Refer to Table 19 and the Insulation Lifetime section
for more information about the recommended maximum working voltages for specific cross-isolation waveforms and insulation levels.
Table 14.
UL CSA CQC VDE
Recognized Under
UL 1577 Component
Recognition Program
1
Approved under CSA Component
Acceptance Notice 5A
Approved under CQC11-471543-2012 Certified according to
DIN V VDE V 0884-10
(VDE V 0884-10):2006-12
2
Single Protection,
5000 V rms Isolation
Voltage
Basic insulation per CSA 60950-1-07 and
IEC 60950-1, 600 V rms (848 V peak)
maximum working voltage
Basic insulation per GB4943.1-2011,
600 V rms (848 V peak) maximum
working voltage, tropical climate,
altitude ≤ 5000 m
Reinforced insulation,
848 V peak
RW-16 package: reinforced insulation per
CSA 60950-1-07 and IEC 60950-1,
380 V rms (537 V peak) maximum
working voltage; reinforced insulation
per IEC 60601-1, 125 V rms (176 V peak)
maximum working voltage
RW-16 package: reinforced insulation
per GB4943.1-2011, 380 V rms
(537 V peak) maximum working
voltage, tropical climate, altitude ≤
5000 m
RI-16-2 package: reinforced insulation per
CSA 60950-1-07 and IEC 60950-1,
400 V rms (565 V peak) maximum
working voltage; reinforced insulation
per IEC 60601-1, 250 V rms (353 V peak)
maximum working voltage
RI-16 package: reinforced insulation
per 400 V rms (565 V peak) maximum
working voltage, tropical climate,
altitude ≤ 5000 m
File E214100 File 205078 File: CQC14001105917 File 2471900-4880-0001
1
In accordance with UL 1577, each ADuM2200/ADuM2201 is proof tested by applying an insulation test voltage ≥ 6000 V rms for 1 sec (current leakage detection limit = 10 µA).
2
In accordance with DIN V VDE V 0884-10 (VDE V 0884-10):2006-12, each ADuM2200/ADuM2201 is proof tested by applying an insulation test voltage ≥1592 V peak for 1 sec
(partial discharge detection limit = 5 pC). The asterisk (*) marking branded on the components designates DIN V VDE V 0884-10 (VDE V 0884-10):2006-12 approval.
INSULATION AND SAFETY-RELATED SPECIFICATIONS
Table 15.
Parameter Symbol Value Unit Test Conditions/Comments
Rated Dielectric Insulation Voltage 5000 V rms 1-minute duration
Minimum External Air Gap (Clearance) L(I01) 8.0 min mm Distance measured from input terminals to output
terminals, shortest distance through air along the
PCB mounting plane, as an aid to PC board layout
Minimum External Tracking (Creepage)
Measured from input terminals to output terminals,
shortest distance path along body
RW-16 Package 7.7 min mm
RI-16-2 Package 8.3 min mm
Minimum Internal Distance (Internal Clearance) 0.017 min mm Insulation distance through insulation
Tracking Resistance (Comparative Tracking Index) CTI >400 V DIN IEC 112/VDE 0303, Part 1
Isolation Group II Material Group (DIN VDE 0110, 1/89, Table 1)