IR2130/IR2132(J)(S) & (PbF)
www.irf.com 11
Figure 16A. ITRIP to
FAULT
Indication Time vs.
Temperature
Figure 16B. ITRIP to
FAULT
Indication Time vs. Voltage
0.00
0.30
0.60
0.90
1.20
1.50
10 12 14 16 18 20
V
CC
Supply Voltage (V)
ITRIP to FAULT Indication Delay Time (µs)
Max.
Typ.
Min.
0.00
0.30
0.60
0.90
1.20
1.50
-50 -25 0 25 50 75 100 125
Temperature (°C)
ITRIP to FAULT Indication Delay Time (µs)
Typ.
Min.
Max.
Figure 17A.
LIN1,2,3
to
FAULT
Clear Time vs.
Temperature
Figure 17B.
LIN1,2,3
to
FAULT
Clear Time vs. Voltage
0.0
5.0
10.0
15.0
20.0
25.0
-50 -25 0 25 50 75 100 125
Temperature (°C)
LIN1,2,3 to FAULT Clear Time (µs)
Typ.
Min.
Max.
0.0
5.0
10.0
15.0
20.0
25.0
10 12 14 16 18 20
V
CC
Supply Voltage (V)
LIN1,2,3 to FAULT Clear Time (µs)
Max.
Typ.
Min.
Figure 18A. Deadtime vs. Temperature (IR2130) Figure 18B. Deadtime vs. Voltage (IR2130)
0.00
1.50
3.00
4.50
6.00
7.50
-50 -25 0 25 50 75 100 125
Temperature (°C)
Deadtime (µs)
Typ.
Min.
Max.
0.00
1.50
3.00
4.50
6.00
7.50
10 12 14 16 18 20
V
BIAS
Supply Voltage (V)
Deadtime (µs)
Max.
Typ.
Min.