3
Device Selection Guide
Part Number
Color and Dominant
Wavelength λ
d
(nm)
Typ
[3]
Luminous Intensity
Iv (mcd) at 20 mA
[1,2,5]
Stando
Typical Viewing
angle (°)
[4]
Min Max
HLMP-EG1S-Z20DD Red 621 12000 27000 No 15
HLMP-EG1T-Z20DD Red 621 12000 27000 Yes
HLMP-EL1S-Z20DD Amber 590 12000 27000 No
HLMP-EL1S-Z2KDD Amber 590 12000 27000 No
HLMP-EL1S-Z2LDD Amber 590 12000 27000 No
HLMP-EL1T-Z20DD Amber 590 12000 27000 Yes
HLMP-EL1T-Z2KDD Amber 590 12000 27000 Yes
HLMP-EL1T-Z2LDD Amber 590 12000 27000 Yes
HLMP-EG2S-XZ0DD Red 621 7200 16000 No 23
HLMP-EG2T-XZ0DD Red 621 7200 16000 Yes
HLMP-EL2S-XZ0DD Amber 590 7200 16000 No
HLMP-EL2S-XZKDD Amber 590 7200 16000 No
HLMP-EL2S-XZLDD Amber 590 7200 16000 No
HLMP-EL2T-XZ0DD Amber 590 7200 16000 Yes
HLMP-EL2T-XZKDD Amber 590 7200 16000 Yes
HLMP-EL2T-XZLDD Amber 590 7200 16000 Yes
HLMP-EG3S-VX0DD Red 621 4200 9300 No 30
HLMP-EG3T-VX0DD Red 621 4200 9300 Yes
HLMP-EL3S-VX0DD Amber 590 4200 9300 No
HLMP-EL3S-VXKDD Amber 590 4200 9300 No
HLMP-EL3S-VXLDD Amber 590 4200 9300 No
HLMP-EL3T-VX0DD Amber 590 4200 9300 Yes
HLMP-EL3T-VXKDD Amber 590 4200 9300 Yes
HLMP-EL3T-VXLDD Amber 590 4200 9300 Yes
Notes:
1. The luminous intensity is measured on the mechanical axis of the lamp package and it is tested with pulsing condition.
2. The optical axis is closely aligned with the package mechanical axis.
3. Dominant wavelength, λ
d
, is derived from the CIE Chromaticity Diagram and represents the color of the lamp.
4. θ
½
is the o-axis angle where the luminous intensity is half the on-axis intensity.
5. Tolerance for each bin limit is ± 15%