HLMP-EL2V-Z10DD

4
Part Numbering System
Note: Refer to AB 5337 for complete information on the part numbering system.
Packaging Option
DD: Ammopack
HLMP E x xx – x x x xx
Color Bin Selection
0 : Full Distribution
K: Color bin 2 and 4
L: Color bin 4 and 6
Maximum Intensity Bin
Refer to Device Selection Guide
Minimum Intensity Bin
Refer to Device Selection Guide
Viewing Angle and Lead Stando
1S: 15° without stando
1T: 15° with stando
2S: 23° without stando
2T: 23° with stando
3S: 30° without stando
3T: 30° with stando
Color
G: Red 621
L: Amber 590
5
Absolute Maximum Ratings T
J
= 25° C
Parameter Red/ Amber Unit
DC Forward Current
[1]
50 mA
Peak Forward Current 100
[2]
mA
Power Dissipation 120 mW
LED Junction Temperature 130 °C
Operating Temperature Range -40 to +100 °C
Storage Temperature Range -40 to +100 °C
Notes:
1. Derate linearly as shown in Figure 4.
2. Duty Factor 30%, frequency 1 kHz.
Electrical / Optical Characteristics T
J
= 25° C
Parameter Symbol Min. Typ. Max. Units Test Conditions
Forward Voltage
Amber/Red
V
F
1.8 2.1 2.4 V I
F
= 20 mA
Reverse Voltage
[1]
V
R
5 V
I
R
= 100 μA
Dominant Wavelength
[2]
Amber
Red
l
d
587.0
618.0
590.0
621.0
594.5
630.0
nm I
F
= 20 mA
Peak Wavelength
Amber
Red
l
PEAK
594
629
nm Peak of Wavelength of Spec-
tral Distribution at I
F
= 20 mA
Thermal resistance Rq
J-PIN
240 °C/W LED junction to pin
Luminous ecacy
[3]
Amber
Red
h
v
500
205
lm/W Emitted Luminous Flux/
Emitted Radiant Flux
Notes:
1. Indicates product nal testing condition, long term reverse bias is not recommended.
2. The dominant wavelength is derived from the Chromaticity Diagram and represents the color of the lamp.
3. The radiant intensity, Ie in watts per steradian, maybe found from the equation Ie = Iv / ηV where Iv is the luminous intensity in candela and h
v
is
the luminous ecacy in lumens/watt.
6
0.0
0.2
0.4
0.6
0.8
1.0
500 550 600 650 700
RELATIVE INTENSITY
WAVELENGTH - nm
Red
Amber
0
20
40
60
80
100
0 1 2 3 4
FORWARD CURRENT - mA
FORWARD VOLTAGE - V
0.0
0.5
1.0
1.5
2.0
2.5
3.0
3.5
4.0
4.5
5.0
0 10 20 30 40 50 60 70 80 90 100
RELATIVE INTENSITY
FORWARD CURRENT - mA
0.0
10.0
20.0
30.0
40.0
50.0
60.0
0 20 40 60 80 100 120
I
F
- FORWARD CURRENT - mA
T
A
- AMBIENT TEMPERATURE - °C
-2.0
-1.5
-1.0
-0.5
0.0
0.5
1.0
1.5
2.0
0 20 40 60 80 100
DOMINANT WAVELENGTH SHIFT - nm
FORWARD CURRENT - mA
Amber
Red
0
0.2
0.4
0.6
0.8
1
-90 -60 -30 0 30 60 90
NORMALIZED INTENSITY
ANGULAR DISPLACEMENT - DEGREES
Figure 1. Relative Intensity vs Wavelength Figure 2. Forward Current vs Forward Voltage
Figure 3. Relative Intensity vs Forward Current Figure 4. Maximum Forward Current vs Ambient Temperature
Figure 5. Dominant Wavelength Shift vs Forward Current Figure 6. Representative Radiation Pattern for 15° Lamp

HLMP-EL2V-Z10DD

Mfr. #:
Manufacturer:
Broadcom / Avago
Description:
Standard LEDs - Through Hole Lamp,5mm,AlInGaP,Amb 23deg
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union