F-51852GNFJ-SLW-AEN (AE) No. 2005-0268 OPTREX CORPORATION Page 17/23
5. Test
No change on display and in operation under the following test condition.
Conditions: Unless otherwise specified, tests will be conducted under the following condition.
Temperature: 20±5°C
Humidity : 65±5%RH
tests will be not conducted under functioning state.
No. Parameter Conditions Notes
1 High Temperature Operating 70°C±2°C, 96hrs (operation state)
2 Low Temperature Operating -20°C±2°C, 96hrs (operation state) 1
3 High Temperature Storage 80°C±2°C, 96hrs 2
4 Low Temperature Storage -30°C±2°C, 96hrs 1,2
5 Damp Proof Test 40°C±2°C,90~95%RH, 96hrs 1,2
6 Vibration Test Total fixed amplitude : 1.5mm 3
Vibration Frequency : 10~55Hz
One cycle 60 seconds to 3 directions of X, Y, Z for
each 15 minutes
7 Shock Test To be measured after dropping from 60cm high on
the concrete surface in packing state.
Note 1 :No dew condensation to be observed.
Note 2 :The function test shall be conducted after 4 hours storage at the normal
Temperature and humidity after removed from the test chamber.
Note 3 :Vibration test will be conducted to the product itself without putting it in a container.
E
A
G
C
F
60cm
Concrete Surface
Dropping method corner dropping
E,F,G face : once
B,C,D edge : once
A corner : once
Face dropping
Edge dropping
B