2 www.honeywell.com/sensing
Table 1. Specifications
Class B and 2B: -70 °C to 500 °C (continuous
operation)
Class B and 2B: -70 °C to 500 °C (continuous
operation)
Class A: -30 °C to 300 °C
Class A: -30 °C to 300 °C
max. R
0
drift 0.04% after 1000 h at 500 °C
max. R
0
drift 0.04% after 1000 h at 500 °C
at least 40 g acceleration at 10 Hz to 2000 Hz,
depends on installation
at least 40 g acceleration at 10 Hz to 2000 Hz,
depends on installation
at least 100 g acceleration with 8 ms half sine
wave, depends on installation
at least 100 g acceleration with 8 ms half sine
wave, depends on installation
unhoused for dry environments only
unhoused for dry environments only
>100 M at 20 °C; >2 M at 500 °C
>100 M at 20 °C; >2 M at 500 °C
water current (v=0.4 m/s): t
0.5
=0.05 s; t
0.9
=0.15 s
air stream (V=2 m/s): t
0.5
=3.0 s; t
0.9
=10.0 s
water current (v=0.4 m/s): t
0.5
=0.04 s; t
0.9
=0.12 s
air stream (V=2 m/s): t
0.5
=2.2 s; t
0.9
=7.0 s
100 : 0.3 mA to 1.0 mA
1000 : 0.1 mA to 0.3 mA
100 : 0.3 mA to 1.0 mA
1000 : 0.1 mA to 0.3 mA
Class B: -50 °C to 130 °C (continuous operation)
Class B: -50 °C to 130 °C (continuous operation)
end-termination galvanic tin-plated with Ni barrier
layer
end-termination galvanic tin-plated with Ni barrier
layer
max. R
0
drift 0.06 % after 1000 h at 130 °C
max. R
0
drift 0.06 % after 1000 h at 130 °C
unhoused for dry environments only
unhoused for dry environments only
>100 M at 20 °C; >2 M at 130 °C (glass
covering)
>100 M at 20 °C; >2 M at 130 °C (glass
covering)
water current (v=0.4 m/s): t
0.5
=0.10 s; t
0.9
=0.25 s
air stream (V = 2 m/s): t
0.5
=2.5 s; t
0.9
=8.0 s
water current (v=0.4 m/s): t
0.5
=0.15 s; t
0.9
=0.30 s
air stream (V = 2 m/s): t
0.5
=3.5 s; t
0.9
=10.0 s
100 : 0.3 mA to 1.0 mA
1000 : 0.1 mA to 0.3 mA
100 : 0.3 mA to 1.0 mA
1000 : 0.1 mA to 0.3 mA
face up mounting: reflow soldering or wave
soldering, e.g. double wave ≤8 s/235 °C
face up mounting: reflow soldering or wave
soldering, e.g. double wave ≤8 s/235 °C