PCA85162 All information provided in this document is subject to legal disclaimers. © NXP Semiconductors N.V. 2015. All rights reserved.
Product data sheet Rev. 4 — 9 April 2015 7 of 56
NXP Semiconductors
PCA85162
32 x 4 automotive LCD driver for low multiplex rates
7.1.1 Command: mode-set
The mode-set command allows configuring the multiplex mode, the bias levels and
enabling or disabling the display.
[1] The possibility to disable the display allows implementation of blinking under external control.
[2] Default value.
[3] The display is disabled by setting all backplane and segment outputs to V
LCD
.
[4] Not applicable for static drive mode.
7.1.2 Command: load-data-pointer
The load-data-pointer command defines the display RAM address where the following
display data will be sent to.
[1] Default value.
Table 7. Mode-set command bit description
Bit Symbol Value Description
7C0, 1see Table 6
6 to 5 - 10 fixed value
4 - - unused
3E display status
[1]
0
[2]
disabled (blank)
[3]
1 enabled
2B LCD bias configuration
[4]
0
[2] 1
3
bias
1
1
2
bias
1 to 0 M[1:0] LCD drive mode selection
01 static; BP0
10 1:2 multiplex; BP0, BP1
11 1:3 multiplex; BP0, BP1, BP2
00
[2]
1:4 multiplex; BP0, BP1, BP2, BP3
Table 8. Load-data-pointer command bit description
See Section 7.6.1.
Bit Symbol Value Description
7C0, 1see Table 6
6 to 5 - 00 fixed value
4 to 0 P[4:0] 00000
[1]
to
11111
5 bit binary value, 0 to 31; transferred to the data pointer to
define one of 32 display RAM addresses
PCA85162 All information provided in this document is subject to legal disclaimers. © NXP Semiconductors N.V. 2015. All rights reserved.
Product data sheet Rev. 4 — 9 April 2015 8 of 56
NXP Semiconductors
PCA85162
32 x 4 automotive LCD driver for low multiplex rates
7.1.3 Command: device-select
The device-select command allows defining the subaddress counter value.
[1] Default value.
7.1.4 Command: bank-select
The bank-select command controls where data is written to RAM and where it is displayed
from.
[1] The bank-select command has no effect in 1:3 and 1:4 multiplex drive modes.
[2] Default value.
Table 9. Device-select command bit description
See Section 7.6.2.
Bit Symbol Value Description
7C0, 1see Table 6
6 to 3 - 1100 fixed value
2 to 0 A[2:0] 000
[1]
to 111 3 bit binary value, 0 to 7; transferred to the subaddress
counter to define one of eight hardware subaddresses
Table 10. Bank-select command bit description
See Section 7.6.5.
Bit Symbol Value Description
Static 1:2 multiplex
[1]
7 C 0, 1 see Table 6
6 to 2 - 11110 fixed value
1I input bank selection; storage of arriving display data
0
[2]
RAM row 0 RAM rows 0 and 1
1 RAM row 2 RAM rows 2 and 3
0O output bank selection; retrieval of LCD display data
0
[2]
RAM row 0 RAM rows 0 and 1
1 RAM row 2 RAM rows 2 and 3
PCA85162 All information provided in this document is subject to legal disclaimers. © NXP Semiconductors N.V. 2015. All rights reserved.
Product data sheet Rev. 4 — 9 April 2015 9 of 56
NXP Semiconductors
PCA85162
32 x 4 automotive LCD driver for low multiplex rates
7.1.5 Command: blink-select
The blink-select command allows configuring the blink mode and the blink frequency.
[1] Default value.
[2] Normal blinking is assumed when the LCD multiplex drive modes 1:3 or 1:4 are selected.
[3] Alternate RAM bank blinking does not apply in 1:3 and 1:4 multiplex drive modes.
7.1.5.1 Blinking
The display blinking capabilities of the PCA85162 are very versatile. The whole display
can blink at frequencies selected by the blink-select command (see Table 11
). The blink
frequencies are derived from the clock frequency. The ratio between the clock and blink
frequencies depends on the blink mode selected (see Table 12
).
An additional feature is for an arbitrary selection of LCD segments/elements to blink. This
applies to the static and 1:2 multiplex drive modes and can be implemented without any
communication overheads. By means of the output bank selector, the displayed RAM
banks are exchanged with alternate RAM banks at the blink frequency. This mode can
also be specified by the blink-select command.
In the 1:3 and 1:4 multiplex modes, where no alternative RAM bank is available, groups of
LCD segments/elements can blink by selectively changing the display RAM data at fixed
time intervals.
The entire display can blink at a frequency other than the nominal blink frequency. This
can be effectively performed by resetting and setting the display enable bit E at the
required rate using the mode-set command (see Table 7
).
Table 11. Blink-select command bit description
See Section 7.1.5.1.
Bit Symbol Value Description
7C0, 1see Table 6
6 to 3 - 1110 fixed value
2AB blink mode selection
0
[1]
normal blinking
[2]
1 alternate RAM bank blinking
[3]
1 to 0 BF[1:0] blink frequency selection
00
[1]
off
01 1
10 2
11 3

PCA85162T/Q900/1,1