TCN75
DS21490D-page 10 2001-2012 Microchip Technology Inc.
5.0 REGISTER SET AND
PROGRAMMER’S MODEL
TABLE 5-2: CONFIGURATION REGISTER
(CONFIG), 8 BITS, READ/
WRITE
D0: Shutdown:
0 = Normal Operation
1 = Shutdown Mode
D1: CMPTR/INT:
0 = Comparator Mode
1 = Interrupt Mode
D2: INT/CMPTR POLARITY:
0 = Active Low
1 = Active High
D3 – D4: Fault Queue: Number of sequential
temperature-to-digital conversions with the same result
before the INT/CMPTR output is updated:
TABLE 5-1: REGISTER (POINT), 8 BITS,
WRITE ONLY
D[7] D[6] D[5] D[4] D[3] D[2] D[1] D[0]
Must Be Set To Zero Pointer
Register Selection Via the Pointer Register
D1 D0 Register Selection
00 TEMP
01 CONFIG
10 T
HYST
11 T
SET
D
[7]
D
[6]
D
[5]
D
[4]
D
[3]
D
[2]
D
[1]
D
[0]
Must Be Set
To Zero
Fault
Queue
INT/
CMPTR,
Polarity
COM
P/INT
Shut-
down
D4 D3 Number of Conversions
00 1 (Power-up default)
01 2
10 4
11 6
2001-2012 Microchip Technology Inc. DS21490D-page 11
TCN75
TABLE 5-3: TEMPERATURE (TEMP) REGISTER, 16 BITS, READ ONLY
The binary value in this register represents ambient temperature following a conversion cycle.
TABLE 5-4: TEMPERATURE SET POINT (T
SET
) REGISTER, 16 BITS, READ/WRITE
TABLE 5-5: HYSTERESIS (T
HYST
) REGISTER, 16 BITS, READ/WRITE
In the TEMP, T
SET
, and T
HYST
registers, each unit
value represents one-half degree (Celsius). The value
is in 2’s – complement binary format such that a read-
ing of 000000000b corresponds to 0°C. Examples of
this temperature to binary value relationship are shown
in Table 5-6.
TABLE 5-6: TEMPERATURE TO DIGITAL
VALUE CONVERSION
TABLE 5-7: TCN75’S REGISTER SET SUMMARY
D[15] D[14] D[13] D[12] D[11] D[10] D[9] D[8] D[7] D[6] D[5] D[4] D[3] D[2] D[1] D[0]
MSB D7 D6 D5 D4 D3 D2 D1 LSB XXXXX X X
D[15] D[14] D[13] D[12] D[11] D[10] D[9] D[8] D[7] D[6] D[5] D[4] D[3] D[2] D[1] D[0]
MSB D7 D6 D5 D4 D3 D2 D1 LSB XXXXX X X
D[15] D[14] D[13] D[12] D[11] D[10] D[9] D[8] D[7] D[6] D[5] D[4] D[3] D[2] D[1] D[0]
MSB D7 D6 D5 D4 D3 D2 D1 LSB XXXXX X X
Temperature Binary Value HEX Value
+125°C 0 11111010 0FA
+25°C 0 00110010 032
+0.5°C 0 00000001 001
0°C 0 00000000 00
0.5°C 1 11111111 1FF
-25°C 1 11001110 1CE
-40°C 1 10110000 1B0
-55°C 1 10010010 192
Name Description Width Read Write Notes
TEMP Ambient Temperature 16 X 2’s Complement Format
TSET Temperature Setpoint 16 XX2’s Complement Format
T
HYST
Temperature Hysteresis 16 XX2’s Complement Format
POINT Register Pointer 8 XX
CONFIG Configuration Register 8 XX
TCN75
DS21490D-page 12 2001-2012 Microchip Technology Inc.
FIGURE 5-1: Timing Diagrams
1
1
Start
by
Master
Ack
by
TCN75
Address Byte
(a) Typical 2-Byte Read From Preset Pointer Location Such as Temp, T
OS
, T
HYST
(b) Typical Pointer Set Followed by Immediate Read for 2-Byte Register Such as Temp, T
OS
, T
HYST
Ack
by
Master
Most Significant Data Byte
Stop
Cond
by
Master
No Ack
by
Master
Least Significant Data Byte
D7 D6 D5
D4
D3 D2 D1 D0 D7 D6 D5 D4 D3 D2 D1 D01A2A1A0
R/W
00
19199
1
1
Start
by
Master
Ack
by
TCN75
Address Byte
Ack
by
TCN75
Pointer Byte
000000D1 D0
. . . . .
. . . . .
1 A2 A1 A0
R/W
00
199
1
1
Start
by
Master
Ack
by
TCN75T
Address Byte
(c) Typical 1-Byte Read From Configuration Register with Preset Pointer
Data Byte
Stop
Cond
by
Master
No Ack
by
Master
D7 D6 D5 D4 D3 D2 D1 D01 A2 A1 A0
R/W
00
199
1
1
Repeat
Start
by
Master
Ack
by
TCN75
Address Byte
Ack
by
Master
Most Significant Data Byte
Stop
Cond
by
Master
No Ack
by
Master
Least Significant Data Byte
D7 D6 D5 D4 D3 D2 D1 D0 D7 D6 D5 D4 D3 D2 D1 D01 A2 A1 A0
R/W
00
19199