2308302

MCR-SL-CUC-...-...
104059_en_05 PHOENIX CONTACT 4
Connection data
Outside diameter of input 32 mm Ø
Power supply/output conductor cross-section
Solid (minimum/maximum)
Stranded (minimum/maximum)
Stranded with ferrule without plastic sleeve (minimum/maximum)
Stranded with ferrule with plastic sleeve (minimum/maximum)
AWG/kcmil (minimum/maximum)
0.2...2.5mm
2
0.2...2.5mm
2
0.25 ... 2.5 mm
2
0.25 ... 1.5 mm
2
24 ... 14
Stripping length (power supply/output) 10 mm
General data
Supply voltage 24 V DC
Supply voltage range U
B
20 ... 30 V DC
Current consumption
MCR-SL-CUC-...-I
MCR-SL-CUC-...-U
30 mA + I
OUT
30 mA
Power consumption
At U
Bmax
= 30 V and I
OUT
= 25 mA 1.65 W
Transmission error
Under nominal conditions (25°C) < ±1% of range final value (I
N
)
Linearity error < ±1% of range final value (I
N
)
Temperature coefficient
0 … 60°C
-40 … 65°C
±3.2 µA/K
±6.4 µA/K
Step response (90% of I
N
) 150 ms
Ambient temperature range
Operation
Storage
-40°C ... +65°C
-40°C ... +85°C
Safe isolation according to EN 61010
Rated insulation voltage
300 V AC
Test voltage
Input/output
Input/power supply
3.5 kV, 50 Hz, 1 min.
3.5 kV, 50 Hz, 1 min.
Surge voltage category (measurement category according to EN 61010) III
Pollution degree 2
Degree of protection IP20
Dimensions (W x H x D) 90 mm x 70 mm x 33.8 mm
Housing version Frianyl B63 V0 GV30
The current transducer housing meets the requirements of
UL94-V0 regarding inflammability characteristics.
Approvals
UL, USA / Canada (does not apply to 2308085, 2308098)
Conformance with EMC Directive 2004/108/EC and Low Voltage Directive 2006/95/EC
EMC requirements regarding noise immunity and noise emission EN 61326-1:2006
General requirements regarding electrical safety EN 61010-1:2001
MCR-SL-CUC-...-...
104059_en_05 PHOENIX CONTACT 5
5 Safety notes and warning
instructions
Dimensions (nominal sizes in mm)
90
Ø32
70
71,2
16
25
10
4,6
12,5
33,8
78
6
4,6
Installation and startup must only be carried out
by qualified electricians. When installing and
operating the device, the applicable safety
directives (including national safety directives),
accident prevention regulations, as well as
general technical regulations, must be observed.
In terms of these operating instructions, qualified
personnel are electricians or persons with
electrotechnical training as defined in VDE 0105
Part 1/DIN EN 50110-1.
WARNING:
Disregarding this warning may result in damage
to equipment and/or serious personal injury.
NOTE:
Safe and error-free operation of this device can
only be ensured if transport, storage, and
assembly are carried out correctly and operation
and maintenance are carried out with care.
MCR-SL-CUC-...-...
104059_en_05 PHOENIX CONTACT 6
6Block diagram
Figure 1 Block diagram for current output
Figure 2 Block diagram for voltage output
7 Structure
Figure 3 Structure
1. Input cable feed-through for the primary live conductor
2. Standard output signal and supply voltage
(FKCN 2,5/ 4-ST COMBICON connector)
3. Connection option for DIN rail adapter
4. Fixing holes for wall mounting, Ø 4.5 mm
5. Marking option with flat zack marker strips
8Mounting
Figure 4 Mounting
The current transducers can be snapped onto all 35 mm DIN
rails according to EN 60715 using the two
PACT MCR-RA DIN rail adapters provided.
Alternatively, the current transducers can also be wall-
mounted using the fixing holes (see Figure 3, "Structure").
Please use appropriate mounting material for this
(e.g., M4 x 20 cylinder head screw).
IN
1.3
1.4
1.2
1.1
GND
NC
OUT I
+24 V DC
ADC
µC
DAC
I
IN
1.3
1.4
1.2
1.1
GND
OUT U
NC
+24VDC
ADC
µC
DAC
U
3
2
5
1
3
4
4
Mounting material for wall mounting is not
supplied as standard.
The requirements for the protection class must be
met by means of installation in suitable housing.
A
B
PACT MCR-RA

2308302

Mfr. #:
Manufacturer:
Phoenix Contact
Description:
Current Transformer Sensors Current Transformers MCR-SL-CUC-300-U
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union

Products related to this Datasheet