4
Optical/Electrical Characteristics at T
A
=25°C
Test
Symbol Parameter Device Min. Typ.
[3]
Max. Units Conditions
2q
1
/
2
Included Angle Between Half HLMP-C008 8 Deg. I
F
= 20 mA
Luminous Intensity Points
[1]
HLMP-C208 8 See Note 1
HLMP-C608 8
HLMP-C025 25
HLMP-C225 25
HLMP-C325 25
HLMP-C625 25
HLMP-C610 8
HLMP-C027 25
HLMP-C627 25
l d
Dominant Wavelength
[2]
HLMP-C008 626 nm See Note 2
HLMP-C208 590
HLMP-C608 635
HLMP-C025 626
HLMP-C225 590
HLMP-C325 605
HLMP-C625 635
HLMP-C610 635
HLMP-C027 626
HLMP-C627 635
l PEAK
Peak Wavelength HLMP-C008 635 nm Measurement at Peak
HLMP-C208 594
HLMP-C608 650
HLMP-C025 635
HLMP-C225 594
HLMP-C325 611
HLMP-C625 650
HLMP-C610 650
HLMP-C027 635
HLMP-C627 650
Dl
1
/
2
Spectral Line Halfwidth 17 nm
t
s
Speed of Response 20 ns
C Capacitance 40 pF V
F
= 0; f = 1 MHz
Rq
J-PIN
Thermal Resistance 260 °C/W Junction to Cathode Lead
V
F
Forward Voltage HLMP-C008 1.9 2.4 V I
F
= 20 mA
HLMP-C208 1.9 2.6
HLMP-C608 1.9 2.2
HLMP-C025 1.9 2.4
HLMP-C225 1.9 2.6
HLMP-C625 1.9 2.2
HLMP-C610 1.9 2.2
HLMP-C027 1.9 2.4
HLMP-C627 1.9 2.2
V
R
Reverse Breakdown Voltage 5.0 V I
R
= 100 µA
Notes:
1.
q
1
/
2
is the o-axis angle at which the luminous intensity is half of the axial luminous intensity.
2.
The dominant wavelength, l
d
, is derived from the CIE chromaticity diagram and represents the single wavelength which denes the color of the
device.