NTB0102 All information provided in this document is subject to legal disclaimers. © NXP B.V. 2013. All rights reserved.
Product data sheet Rev. 4 — 23 January 2013 13 of 26
NXP Semiconductors
NTB0102
Dual supply translating transceiver; auto direction sensing; 3-state
[1] V
CCI
is the supply voltage associated with the input and V
CCO
is the supply voltage associated with the output.
Measurement points are given in Table 14
.
V
OL
and V
OH
are typical output voltage levels that occur with the output load.
Fig 7. Enable and disable times
001aal919
t
PLZ
t
PHZ
outputs
disabled
outputs
enabled
outputs
enabled
output
LOW-to-OFF
OFF-to-LOW
output
HIGH-to-OFF
OFF-to-HIGH
OE input
V
OH
V
CCO
GND
V
OL
GND
V
I
t
PZL
t
PZH
V
Y
V
M
V
M
V
X
V
M
Table 14. Measurement points
[1]
Supply voltage Input Output
V
CCO
V
M
V
M
V
X
V
Y
1.2 V 0.5V
CCI
0.5V
CCO
V
OL
+ 0.1 V V
OH
0.1 V
1.5 V 0.1 V 0.5V
CCI
0.5V
CCO
V
OL
+ 0.1 V V
OH
0.1 V
1.8 V 0.15 V 0.5V
CCI
0.5V
CCO
V
OL
+ 0.15 V V
OH
0.15 V
2.5 V 0.2 V 0.5V
CCI
0.5V
CCO
V
OL
+ 0.15 V V
OH
0.15 V
3.3 V 0.3 V 0.5V
CCI
0.5V
CCO
V
OL
+ 0.3 V V
OH
0.3 V
5.0 V 0.5 V 0.5V
CCI
0.5V
CCO
V
OL
+ 0.3 V V
OH
0.3 V
NTB0102 All information provided in this document is subject to legal disclaimers. © NXP B.V. 2013. All rights reserved.
Product data sheet Rev. 4 — 23 January 2013 14 of 26
NXP Semiconductors
NTB0102
Dual supply translating transceiver; auto direction sensing; 3-state
[1] V
CCI
is the supply voltage associated with the input.
[2] For measuring data rate, pulse width, propagation delay and output rise and fall measurements, R
L
= 1 M; for measuring enable and
disable times, R
L
= 50 k.
[3] V
CCO
is the supply voltage associated with the output.
Test data is given in Table 15
.
All input pulses are supplied by generators having the following characteristics: PRR 10 MHz; Z
O
= 50 ; dV/dt 1.0 V/ns.
R
L
= Load resistance.
C
L
= Load capacitance including jig and probe capacitance.
V
EXT
= External voltage for measuring switching times.
Fig 8. Test circuit for measuring switching times
V
M
V
M
t
W
t
W
10 %
90 %
0 V
V
I
V
I
negative
pulse
positive
pulse
0 V
V
M
V
M
90 %
10 %
t
f
t
r
t
r
t
f
001aal920
V
EXT
V
CC
V
I
V
O
DUT
C
L
R
L
R
L
G
Table 15. Test data
Supply voltage Input Load V
EXT
V
CC(A)
V
CC(B)
V
I
[1]
t/V C
L
R
L
[2]
t
PLH
, t
PHL
t
PZH
, t
PHZ
t
PZL
, t
PLZ
[3]
1.2 V to 3.6 V 1.65 V to 5.5 V V
CCI
1.0ns/V 15pF 50k, 1 M open open 2V
CCO
NTB0102 All information provided in this document is subject to legal disclaimers. © NXP B.V. 2013. All rights reserved.
Product data sheet Rev. 4 — 23 January 2013 15 of 26
NXP Semiconductors
NTB0102
Dual supply translating transceiver; auto direction sensing; 3-state
13. Application information
13.1 Applications
Voltage level-translation applications. The NTB0102 can be used to interface between
devices or systems operating at different supply voltages. See Figure 9
for a typical
operating circuit using the NTB0102.
Fig 9. Typical operating circuit
001aam487
1.8 V
SYSTEM
CONTROLLER
3.3 V
SYSTEM
1.8 V 3.3 V
0.1 μF 0.1 μF
V
CC(A)
OE
A1
DATA DATA
GND
NTB0102
A2
B1
B2
V
CC(B)

NTB0102GF,115

Mfr. #:
Manufacturer:
NXP Semiconductors
Description:
Translation - Voltage Levels DUAL XCVR AUTO DRECT SENSING; 3-STATE
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union

Products related to this Datasheet