NCP1361, NCP1366
www.onsemi.com
4
PIN FUNCTION DESCRIPTION
Pin out
NCP1366
Pin out
NCP1361
Name Function
1 6 V
s
/ZCD Connected to the auxiliary winding; this pin senses the voltage output for the primary
regulation and detects the core reset event for the Quasi−Resonant mode of operation.
2 5 FB This pin connects to an optocoupler collector and adjusts the peak current setpoint.
3 4 CS This pin monitors the primary peak current.
4 3 DRV Controller switch driver.
5 2 GND Ground reference.
6 1 V
CC
This pin is connected to an external auxiliary voltage and supplies the controller.
7 − NC Not Connected for creepage distance between high and low Voltage pins
8 − HV Connected the high−voltage rail, this pin injects a constant current into the V
CC
capaci-
tor for starting−up the power supply.
MAXIMUM RATINGS
Symbol Rating Value Unit
V
CC(MAX)
Maximum Power Supply voltage, VCC pin, continuous voltage −0.3 to 28 V
ΔV
CC
/Δt Maximum slew rate on V
CC
pin during startup phase +0.4
V/ms
V
DRV(MAX)
I
DRV(MAX)
Maximum driver pin voltage, DRV pin, continuous voltage
Maximum current for DRV pin
−0.3, V
DRV
(Note 1)
−300, +500
V
mA
V
MAX
I
MAX
Maximum voltage on low power pins (except pins DRV and VCC)
Current range for low power pins (except pins DRV and VCC)
−0.3, 5.5
−2, +5
V
mA
V
HV
High Voltage pin voltage −0.3 to 560 V
R
θ
J−A
Thermal Resistance Junction−to−Air 200 °C/W
T
J(MAX)
Maximum Junction Temperature 150 °C
Operating Temperature Range −40 to +125 °C
Storage Temperature Range −60 to +150 °C
Human Body Model ESD Capability per JEDEC JESD22−A114F 2 kV
Machine Model ESD Capability (All pins except DRV) per JEDEC JESD22−A115C 200 V
Charged−Device Model ESD Capability per JEDEC JESD22−C101E 500 V
Stresses exceeding those listed in the Maximum Ratings table may damage the device. If any of these limits are exceeded, device functionality
should not be assumed, damage may occur and reliability may be affected.
1. V
DRV
is the DRV clamp voltage V
DRV(high)
when V
CC
is higher than V
DRV(high)
. V
DRV
is V
CC
otherwise
2. This device contains latch−up protection and exceeds 100 mA per JEDEC Standard JESD78.