ELECTRICAL CHARACTERISTICS: (V
CC
= 12 V, C
DRV
= 1 nF, For typical values T
J
= 25°C, for min/max values T
J
= −40°C to
+125°C, Max T
J
= 150°C, unless otherwise noted)
Characteristics UnitMaxTypMinSymbolConditions
REGULATION BLOCK
Maximum Operating Frequency
Option
Option
f
MAX
75
103
No
Clamp
80
110
85
117
N/A
kHz
kHz
DEMAGNETIZATION INPUT − ZERO VOLTAGE DETECTION CIRCUIT and VOLTAGE SENSE
V
ZCD
threshold voltage V
ZCD
decreasing V
ZCD(TH)
25 45 65 mV
V
ZCD
Hysteresis V
ZCD
increasing V
ZCD(HYS)
15 30 45 mV
Threshold voltage for output
short circuit or aux. winding
short circuit detection
After t
BLANK_ZCD
if V
ZCD
< V
ZCD(short)
Ù Latched
V
ZCD(short)
30 50 70 mV
Propagation Delay from valley
detection to DRV high
V
ZCD
decreasing from 4 V to 0 V t
DEM
170 ns
Delay after on−time that the
V
s
/ZCD is still pulled to ground
(Note 4) t
short_ZCD
0.7
ms
Blanking delay after on−time
(V
s
/ZCD pin is disconnected
from the internal circuitry)
t
blank_ZCD
1.2 1.5 1.8
ms
Timeout after last
demagnetization transition
Timeout while in Soft−start
Timeout after soft−start complete
t
outSS
t
out
36
4.5
44
5.5
52
6.5
ms
Input leakage current V
CC
> V
CC(on)
V
ZCD
= 4 V, DRV is low I
ZCD
0.1
mA
DRIVE OUTPUT − GATE DRIVE
Drive resistance
DRV Sink
DRV Source
R
SNK
R
SRC
7
12
W
Rise time C
DRV
= 1 nF, from 10% to 90% t
r
45 80 ns
Fall time C
DRV
= 1 nF, from 90% to 10% t
f
30 60 ns
DRV Low voltage V
CC
= V
CC(off)
+ 0.2 V,
C
DRV
= 220 pF, R
DRV
= 33 kW
V
DRV(low)
6.0 V
DRV High voltage V
CC
= V
CC(OVP)
−0.2 V
,
C
DRV
= 220 pF,
R
DRV
= 33 kW
V
DRV(high)
13.0 V
SOFT START
Internal Fixed Soft Start
Duration
Current Sense peak current rising from
0.2 V to 0.8 V
t
SS
3 4 5 ms
FAULT PROTECTION
Thermal Shutdown
Device switching (F
sw
65 kHz)
(Note 4)
T
SHTDN
150 °C
Thermal Shutdown Hysteresis Device switching (F
sw
65 kHz)
(Note 4)
T
SHTDN(HYS)
40 °C
Number of Drive cycle before
latch confirmation
V
Comp
= V
Comp(max)
,
V
CS
> V
CS(stop)
Or Internal sampled V
out
> V
OVP
T
latch_count
4
Product parametric performance is indicated in the Electrical Characteristics for the listed test conditions, unless otherwise noted. Product
performance may not be indicated by the Electrical Characteristics if operated under different conditions.
3. The timer can be reset if there are 4 DRV cycles without overload or short circuit conditions
4. Guaranteed by Design.
* Characterization upon request
NCP1361, NCP1366
www.onsemi.com
8
ELECTRICAL CHARACTERISTICS: (V
CC
= 12 V, C
DRV
= 1 nF, For typical values T
J
= 25°C, for min/max values T
J
= −40°C to
+125°C, Max T
J
= 150°C, unless otherwise noted)
Characteristics UnitMaxTypMinSymbolConditions
FAULT PROTECTION
Fault level detection for OVP Ù
Latched or Double Hiccup
autorecovery (depends on fault
version)
Internal sampled V
out
increasing
V
OVP
= V
ref_CV2
+26%
Version E
V
OVP
2.95
3.4
3.15
3.6
3.35
3.8
V
Fault level detection for UVP Ù
Double Hiccup autorecovery
(UVP detection is disabled
during T
EN_UVP
)
Internal sampled V
out
decreasing
Fault Mode Option A & B
Fault Mode Option Version E
V
UVP
1.4
0.70
1.5
0.75
1.6
0.80
V
Blanking time for UVP
detection
Starting at the beginning of the Soft
start
T
EN_UVP
37 ms
Pull−up Current Source on CS
pin for Open or Short circuit
detection
When V
CS
> V
CS_min
I
CS
55
mA
CS pin Open detection CS pin open V
CS(open)
0.8 V
CS pin Short detection V
CS_min
50 70 mV
CS pin Short detection timer (Note 4) T
CS_short
3
ms
Product parametric performance is indicated in the Electrical Characteristics for the listed test conditions, unless otherwise noted. Product
performance may not be indicated by the Electrical Characteristics if operated under different conditions.
3. The timer can be reset if there are 4 DRV cycles without overload or short circuit conditions
4. Guaranteed by Design.
* Characterization upon request
NCP1361, NCP1366
www.onsemi.com
9
FAULT MODE STATES TABLE (WHATEVER THE VERSION)
Event
Timer
Protection
Next Device Status Release to Normal Operation Mode
Overcurrent
V
CS
> V
ILIM
OCP timer Double Hiccup
Resume to normal operation: if 4 pulses from FB
Reset & then Reset timer
Resume operation after Double Hiccup
Winding short
V
CS
> V
CS(stop)
Immediate 4 consecutive pulses with
V
CS
> V
CS(stop)
before
Latching
V
CC
is decreasing to V
CC(clamp)
and waiting for unplug
from line
V
CC
< V
CC(reset)
CS pin Fault:
Short & Open
Immediate Double Hiccup Resume operation after Double Hiccup
Low supply
V
CC
< V
CC(off)
10 ms timer
Double Hiccup Resume operation after Double Hiccup
Internal TSD
10 ms timer
Double Hiccup Resume operation after Double Hiccup & T < (T
SHTDN
− T
SHTDN(Hyst)
)
ZCD short
V
ZCD
< V
ZCD(short)
after
t
BLANK_ZCD
time
Immediate Double Hiccup Resume operation after Double Hiccup (V
CC(on)
< V
CC
< V
CC(reset)
)
FAULT MODE STATES TABLE (ACCORDING TO THE CONTROLLER VERSIONS)
Event A Version B Version C Version
High supply
V
CC
> V
CC(ovp)
Latched_Timer Autorecovery Latched_Timer
Internal V
out
OVP: V
out
> 126% V
ref_CV2
Latched_4clk Autorecovery Latched_4clk
Internal V
out
UVP: V
out
< 60%
V
ref_CV2
, when V
out
is decreasing only
Autorecovery Autorecovery Latched_Timer
FAULT TYPE MODE DEFINITION
Fault Mode Timer Protection Next Device Status Release to Normal Operation Mode
Latched_Timer
10 ms timer
Latched V
CC
is decreasing to V
CC(clamp)
and waiting for un-
plug from line
V
CC
< V
CC(reset)
Latched_4clk Immediate 4 consecutive pulses with
V
CS
> 126% V
ref_CV2
before
Latching
V
CC
is decreasing to V
CC(clamp)
and waiting for un-
plug from line
V
CC
< V
CC(reset)
Autorecovery Immediate Resume operation after
Double Hiccup
Resume operation after Double Hiccup (V
CC(on)
<
V
CC
< V
CC(reset)
)

NCP1366BABAYDR2G

Mfr. #:
Manufacturer:
ON Semiconductor
Description:
Switching Controllers NCP1365 HV CONTROLLER
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union