LT6 020/LT6020-1
6
60201fa
For more information www.linear.com/LT6020
Note 1: Stresses beyond those listed under Absolute Maximum Ratings
may cause permanent damage to the device. Exposure to any Absolute
Maximum Rating condition for extended periods may affect device
reliability and lifetime.
Note 2: Guaranteed by design.
Note 3: The slew rate of the LT6020 increases with the size of the
input step. At lower supplies, the input step size is limited by the input
common mode range. This trend can be seen in the Typical Performance
Characteristics.
elecTrical characTerisTics
SYMBOL PARAMETER CONDITIONS MIN TYP MAX UNITS
I
S
Supply Current per Amplifier
T
A
= –40° to 85°C
T
A
= –40° to 125°C
l
l
85 95
120
135
μA
μA
μA
Supply Current in Shutdown V
EN
= 0.8V
T
A
= –40° to 85°C
T
A
= –40° to 125°C
l
l
0.9 1.1
1.5
3
μA
μA
μA
t
s
Settling Time (A
V
= –1) 0.1% 2.4V Output Step
0.01% 2.4V Output Step
0.0015% 2.4V Output Step
12.4
21.2
39.2
μs
μs
μs
t
ON
Enable Time A
V
= 1 120 µs
V
DGND
DGND Pin Voltage Range
l
V
–
V
+
– 3 V
I
DGND
DGND Pin Current –200 nA
I
EN
EN Pin Current –100 nA
V
ENL
EN Pin Input Low Voltage Relative to DGND
l
0.8 V
V
ENH
EN Pin Input High Voltage Relative to DGND
l
1.7 V
The l denotes the specifications which apply over the specified
temperature range, otherwise specifications are at T
A
= 25°C, V
S
= 3V, V
CM
= V
OUT
= Mid-Supply, V
DGND
= 0V, V
EN
= 3V. DGND and
EN pin specifications only apply to the LT6020-1.