Product Data Sheet 8312 HL-156
11/05/2014 page 5 of 10
3.2 Electrical Operating Data
Measurement
conditions:
Normal air density = 1,2 kg/m3; Temperature 23°C +/- 3°C; Motor axis horizontal;warm-up
time before measuring 5 minutes (unless otherwise specified).In the intake and outlet area
should not be any solid obstruction within 0,5 m.
∆p = 0: corresp. to free air flow (see section 3.5)
I: corresp. to arithm. mean current value
Voltage range ∆p = 0 U 6,0 V 15,0 V
Nominal voltage ∆p = 0 U
12,0 V
Power consumption
∆p = 0
0001
P
0,9 W 4,0 W 6,6 W
Tolerance
+- 17,5 % +- 12,5 % +- 15,0 %
Current consumption
∆p = 0
0001
I
150 mA 333 mA 440 mA
Tolerance
+- 17,5 % +- 12,5 % +- 15,0 %
Speed
∆p = 0
0001
n
2.250 1/min 4.200 1/min 5.000 1/min
Tolerance
+- 12,5 % +- 7,5 % +- 10,0 %
Starting current
consumption
1.780 mA
3.3 Operating Data - Electrical Interface -Output
Tacho type None
Alarm type None