Product Data Sheet 8312 HL-156
11/05/2014 page 7 of 10
3.5 Aerodynamic
Measurement
conditions:
Measured with a double chamber intake rig acc. to DIN EN ISO 5801.
Normal air density = 1,2 kg/m3; Temperature 23°C +/- 3°C;
In the intake and outlet area should not be any solid obstruction within 0,5 m.
The information is only valid under the specified test conditions and may be changed by the
installation conditions. If there are deviations from the standard test conditions, the
characteristic values must be checked under the installed conditions.
a.) Operation condition:
4.200 1/min at free air flow
Max. free-air flow (p = 0 /
= max.) 67,0 m3/h
Max. static pressure (p = max. /
=0) 100 Pa
Product Data Sheet 8312 HL-156
11/05/2014 page 8 of 10
3.6 Sound Data
Measurement
conditions:
Sound pressure level: 1 Meter distance between microphone and the air intake.
Sound power level: Acc. to DIN 45635 part 38 (ISO 10302)
Measured in a semianchoic chamber with a background noise level of Lp(A) < 5 dB(A)
For further measurement conditions see section 3.5
a.) Operation condition:
4.200 1/min at free air flow
Optimal operating point 53,0 m3/h @ 25 Pa
Sound power level at the optimal operating
point
5,8 bel(A)
Sound pressure level at free air flow,
measured in rubber bands
43,0 dB(A)
4 Environment
4.1 General
Min. permitted ambient temperature TU min. -20 °C
Max. permitted ambient temperature TU max. 75 °C
Min. permitted storage temperature TL min. -40 °C
Max. permitted storage temperature TL max. 80 °C
4.2 Climatic requirements*)
Humidity requirements humid heat, constant; according to DIN EN 60068-2-
78, 14 days
Water exposure None
Dust requirements None
Salt fog requirements None
*) Permittet application area:
The product is intended for use in sheltered rooms with controlled temperature and controlled humidity. Directly
exposure to water must be avoided.
Pollution degree 1 (according DIN EN 60664-1)
There is either no pollution or it occurs only dry, non-conductive pollution. The pollution has no negative impact.Please
require severity levels and specification parameters from the responsible development departments
Product Data Sheet 8312 HL-156
11/05/2014 page 9 of 10
5 Safety
5.1 Electrical Safety
Dielectric strength
DIN EN 60950 (VDE 0805) and DIN EN 60335 (VDE
0700)
A.) Type test
Measuring conditions: After 48h of storage at 95%
R.H. and 25°C.
No arcing or breakdown is allowed!
All connections together to ground.
500 VAC / 1 Min.
B.) Routine test
Measuring conditions: At indoor climate.
No arcing or breakdown is allowed!
All connections together to ground.
500 VAC / 1 Sec.
Isolation resistance
Measuring conditions: After 48h of storage at 95%
R.H. and 25°C measured with U=500 VDC for 1 min.
RI > 10 MOhm
clearance / creepage distance 1,0 mm / 1,2 mm
Protection class III
5.2 Approval Tests
CE Yes
UL Yes / UL507, Electric Fans
VDE Yes / Approval acc. to EN 60950 (VDE 0805) - Information
technology equipment
CSA Yes / C22.2 No. 113 Fans and Ventilators
CCC No
The approval tests are observed to:
U approval max.:15,0 V @ TU approval max.: 75,0 °C
6 Reliability
6.1 General
Life expectancy L10 at TU = 40 °C 62.500 h
Life expectancy L10 at TU max. 27.500 h
Life expectancy L10 Delta (40 °C) 122.500 h