14 of 21 June 20, 2000
79RC32364™
*Notice: The information in this document is subject to change without notice
Output Loading For AC Testing
Output Loading For AC Testing Output Loading For AC Testing
Output Loading For AC Testing
Figure 3 Output Loading for AC Testing
Power Consumption
Power ConsumptionPower Consumption
Power Consumption
—
——
—
RC32364
RC32364RC32364
RC32364
Capacitive Load Deration — RC32364
Capacitive Load Deration — RC32364Capacitive Load Deration — RC32364
Capacitive Load Deration — RC32364
Signal Cld
All Signals 50 pF
Parameter
RC32364 100MHz RC32364 133MHz
Conditions
Typical Maximum Typical Maximum
System Condition: 100/50MHz 133/67MHz —
I
CC
standby
1
1.
Executing wait instruction
50mA 90mA 50mA 90mA C
L
= 50pF
T
c
= 25
o
C
Vcc core & Vcc I/O = 3.65V
active 160mA 180mA 200mA 250mA C
L
= 50pF
T
C
= 25
o
C
Vcc core, Vcc I/O = 3.65V
P power
dissipation
0.58W 0.6W 0.7Watt 0.9 C
L
= 50pF
T
C
= 25
o
C
Vcc core, Vcc I/O = 3.65V
Parameter Symbol
Test
Conditions
100MHz 133MHz
Units
Min Max Min Max
Load Derate C
LD
— —2—2ns/25pF
–
+
To Device
Under Test
C
LD
V
REF
+1.5V