MAX4550/MAX4570
Serially Controlled, Dual 4x2, Clickless
Audio/Video Analog Crosspoint Switches
6 _______________________________________________________________________________________
INTERFACE I/O CHARACTERISTICS (continued)
(V+ = +2.7V to +5.5V, V- = 0 to -5.5V, T
A
= T
MIN
to T
MAX
, unless otherwise noted. Typical values are at T
A
= +25°C.) (Note 2)
CONDITIONS UNITSMIN TYP MAXSYMBOLPARAMETER
ns200t
CL
SCLK Pulse Width High
ns200t
CH
SCLK Pulse Width Low
µs2.0t
R
Rise Time (SCLK, DIN, CS)
µs2.0t
F
Fall Time (SCLK, DIN, CS)
Note 2: The algebraic convention is used in this data sheet; the most negative value is shown in the minimum column.
Note 3: Guaranteed by design. Not subject to production testing.
Note 4: ∆R
ON
= R
ON(MAX)
- R
ON(MIN)
.
Note 5: On-resistance flatness is defined as the difference between the maximum and minimum on-resistance values, as measured
over the specified analog signal range.
Note 6: Leakage parameters are 100% tested at maximum rated temperature, and guaranteed by correlation at T
A
= +25°C.
Note 7: Off-isolation = 20
· log (V
COM_ __
/ V
NO_ _
), V
COM_ _
= output, V
NO_ _
= input to off switch.
Note 8: All timing is measured from the clock’s falling edge preceding the ACK signal for 2-wire, and from CS’s rising edge for
3-wire. Turn-Off Time is defined as the output of the switch for 0.5V change, tested with a 300Ω load to ground. Turn-On
Time is measured with a 5kΩ load resistor to GND. All timing is shown with respect to 20% of V+ and 70% of V+, unless
otherwise noted.
Note 9: Typical values are for MAX4570 only.
Note 10: Supply current can be as high as 2mA per switch during switch transitions in the clickless mode, corresponding to 40mA
total supply transient current requirement.
Note 11: Leakage testing for single-supply operation is guaranteed by testing with dual supplies.
Note 12: Cb = capacitance of one bus line in pF. Tested with Cb = 400pF.