9
EPCOS AG
Please read the important notes, cautions and warnings.
The internal structure of single-ended capacitors might be damaged if excessive force is applied to the lead wires.
Stresses like push, pull, bend, etc. might cause increased leakage current, intermittent capacitance, electrolyte leak-
age or open/short circuit, due to rupture of terminals or internal elements.
The following actions should be avoided:
Moving the capacitor after soldering to the PC board.
Picking up the PC board by holding the soldered capacitor.
Inserting the capacitor on the PC board with a hole space different to the specified lead space.
Specifications and characteristics in brief Product
Example
Mounting considerations
KAL0708-N-E
Incorrect
mounting
Incorrect
mounting mounting
IncorrectCorrect
mounting
07/05
10
EPCOS AG
Important notes
The following applies to all products
named in this publication:
1. Some parts of this publication
contain statements about the
suitability of our products for
certain areas of application.
These statements are based on
our knowledge of typical require-
ments that are often placed on
our products in the areas of appli-
cation concerned. We never-
theless expressly point out that
such statements cannot be re-
garded as binding statements
about the suitability of our
products for a particular cus-
tomer application. As a rule,
EPCOS is either unfamiliar with
individual customer applications
or less familiar with them than the
customers themselves. For these
reasons, it is always ultimately
incumbent on the customer to
check and decide whether an
EPCOS product with the proper-
ties described in the product
specification is suitable for use in
a particular customer application.
2. We also point out that in individ-
ual cases, a malfunction of
passive electronic compo-
nents or failure before the end
of their usual service life can-
not be completely ruled out in
the current state of the art,
even if they are operated as
specified. In customer applica-
tions requiring a very high level of
operational safety and especially
in customer applications in which
the malfunction or failure of a pas-
sive electronic component could
endanger human life or health
(e.g. in accident prevention or life-
saving systems), it must therefore
be ensured by means of suitable
design of the customer applica-
tion or other action taken by the
customer (e.g. installation of pro-
tective circuitry or redundancy)
that no injury or damage is sus-
tained by third parties in the event
of malfunction or failure of a pas-
sive electronic component.
3. The warnings, cautions and
product-specific notes must
be observed.
4. In order to satisfy certain technical
requirements, some of the
products described in this
publication may contain sub-
stances subject to restrictions
in certain jurisdictions (e.g.
because they are classed as
“hazardous”). Useful information
on this will be found in our Materi-
al Data Sheets on the Internet
(www.epcos.com/material).
Should you have any more de-
tailed questions, please contact
our sales offices.
5. We constantly strive to improve
our products. Consequently, the
products described in this
publication may change from
time to time. The same is true of
the corresponding product speci-
fications. Please check therefore
to what extent product descrip-
tions and specifications contained
in this publication are still applica-
ble before or when you place an
order.
We also reserve the right to
discontinue production and
delivery of products. Conse-
quently, we cannot guarantee that
all products named in this publi-
cation will always be available.
6. Unless otherwise agreed in indi-
vidual contracts, all orders are
subject to the current version
of the “General Terms of De-
livery for Products and Ser-
vices in the Electrical Indus-
try” published by the German
Electrical and Electronics In-
dustry Association (ZVEI).
7. The trade names EPCOS,
CeraDiode, CSSP, SIMID,
PhaseCap, PhaseMod, SIFI,
SIKOREL, SilverCap, SIOV,
SIP5D, SIP5K, TOPcap,
UltraCap, WindCap are trade-
marks registered or pending in
Europe and in other countries.
Further information will be found
on the Internet at
www.epcos.com/trademarks.
07/05
11
EPCOS AG
Cautions and warnings
The electrolytes used by EPCOS have not only been optimized with a view to the intended application, but also
with regard to health and environmental compatibility. They do not contain any solvents that are detrimental to
health, e.g. dimethyl formamide (DMF) or dimethyl acetamide (DMAC).
Furthermore, part of the high-voltage electrolytes used by EPCOS are self-extinguishing. They contain flame-
retarding substances which will quickly extinguish any flame that may have been ignited.
As far as possible, EPCOS does not use any dangerous chemicals or compounds to produce operating elec-
trolytes. However, in exceptional cases, such materials must be used in order to achieve specific physical and
electrical properties because no safe substitute materials are currently known. However, the amount of danger-
ous materials used in our products has been limited to an absolute minimum. Nevertheless, the following rules
should be observed when handling Al electrolytic capacitors:
Any escaping electrolyte should not come into contact with eyes or skin.
If electrolyte does come into contact with the skin, wash the affected parts immediately with running water.
If the eyes are affected, rinse them for 10 minutes with plenty of water. If symptoms persist, seek medical treat-
ment.
Avoid breathing in electrolyte vapor or mists. Workplaces and other affected areas should be well ventilated.
Clothing that has been contaminated by electrolyte must be changed and rinsed in water.
Personal safety
Make sure that polar capacitors are connected with the right polarity.
Voltages polarity clashes should be prevented by connecting a diode.
Do not damage the insulating sleeve, especially when ring clips are used for mounting.
Do not exceed the upper category temperature (UCT).
Make periodic inspections of the capacitors. Before the inspection, make sure that the power supply
is turned off and carefully discharge the electricity of the capacitors.
Do not apply any mechanical stress to the capacitor terminals.
The internal structure of single-ended capacitors may be damaged if excessive force is applied to
the lead wires.
Avoid any compressive, tensile or flexural stress.
Do not move the capacitor after soldering to the PC board.
Do not pick up the PC board by the soldered capacitor.
Do not insert the capacitor on the PC board with a hole space different to the lead space specified.
Do not exceed the specified time or temperature limits during soldering.
Capacitors should be dipped in solder for less than 10 seconds.
Do not allow halogenated hydrocarbons to come into contact with aluminum electrolytic capacitors.
Avoid external energy, such as fire or electricity.
Avoid overload of the capacitors.
Product safety
Failure to follow cautions and warnings may result in the worst case in premature failure, bursting and fire.
07/05

B41868R8337M

Mfr. #:
Manufacturer:
EPCOS / TDK
Description:
Aluminum Electrolytic Capacitors - Radial Leaded ALUMINUM ELECTROLYTIC RADIAL 330uF 63V
Lifecycle: