ADUX1020-EVAL-SDP User Guide UG1022
Rev. 0 | Page 3 of 9
EVALUATION BOARD SOFTWARE QUICK START PROCEDURES
INSTALLING THE OPTICAL GESTURE EVALUATION
TOOL
Download the Optical Gesture Evaluation Tool software package
from the ADUX1020-EVAL-SDP product page. Unzip the down-
loaded software folder, run the enclosed ADI_OpticalGesture_
EvaluationTool.exe file, and follow the prompts for installing the
Optical Gesture Evaluation Tool software (see Figure 2). For further
information, follow the full installation guide included with the
Optical Gesture Evaluation Tool software in the downloaded folder.
14766-002
Figure 2. Optical Gesture Evaluation Tool Setup
To st ar t the Optical Gesture Evaluation Tool application, navigate
to the ADI_OpticalGesture_EvaluationTool from the Start menu
and click the ADI_OpticalGesture_EvaluationTool icon (see
Figure 3).
14766-003
Figure 3. Navigate to Optical Gesture Evaluation Tool from Start Menu
At startup, the Optical Gesture Evaluation Tool application
automatically checks if the installed Optical Gesture Evaluation
To ol software version is up to date. If there is a newer version
available, the user is prompted to download the newest version.
EVALUATION BOARD USB CONNECTION
Ensure the provided EVAL-SDP-CB1Z controller board and
ADUX1020-EVAL-MCM connect together and connect to a PC
via the USB cable included with the evaluation kit. After the
Optical Gesture Evaluation Tool application opens, click File >
Connect (see Figure 4) and select SDP ASIC Bridge (Debug).
The Optical Gesture Evaluation Tool then acknowledges the
ADUX1020-EVAL-SDP kit is connected.
14766-004
Figure 4. SDP ASIC Connection
CONFIGURING THE ADUX1020-EVAL-SDP
EVALUATION KIT
Before operating the ADUX1020-EVAL-SDP kit, connect any
jumper across Header J7 on the ADUX1020-EVAL-MCM. If
using the ADUX1020-EVALZ-LED daughterboard, disconnect
the jumper from Header J7.
To operate the ADUX1020 in gesture detect mode, click File >
Load Cfg. Select the 004_ADUX1020_StandardR1.dcfg file
and click Open (see Figure 5).
14766-005
Figure 5. Loading the Configuration File
Next, click View > Off-Chip Analysis and Gesture View to open
the Graph XYI tab (see Figure 6). With the evaluation board
positioned so there are no objects around it within at least a 20 cm
radius, click the Channel Auto Calibration button to calibrate the
ADUX1020-EVAL-SDP kit. The Optical Gesture Evaluation Tool
then acknowledges if calibration is successful.