H7GP-TDB

H7GP
4
Connections
Terminal Arrangement
Note: Non-contact input is also available.
5678
4
321
0 V
12 VDC0 V
5678
4
321
12 VDC0 V
5678
4
321
5678
4
321
0 V
AC Models
H7GP-C
H7GP-T
DC Models
H7GP-CD
H7GP-TD
Unused
Unused Unused
12 to 24 VDC
PNP mode
NPN mode
100 to 240 VAC
Unused
NPN mode
PNP mode
100 to 240 VAC
Unused
NPN mode
PNP mode
Unused
Unused Unused
12 to 24 VDC
PNP mode
NPN mode
External power supply
12 VDC 50 mA max.
Power
supply
Power
supply
Key protection
input
Reset
input
Count
input
Power
supply
Key protection
input
Reset
input
Count
input
External power supply
12 VDC 50 mA max.
Power
supply
Power
supply
Key protection
input
Reset
input
Count
input
Power
supply
Key protection
input
Reset
input
Start
input
H7GP
5
Operation
DIP Switch Settings
Set all DIP switches before mounting the Counter to a control panel.
All switches are set toward the display panel before shipping.
H7GP-C/-CD
H7GP-T/-TD
Note: 1. When the setting has been changed, turned power off and
on to continue. The display will show “0” when the power is
turned back on.
2. The decimal point will flash every second when “99999.9 h”
is set.
Operating Modes
Nomenclature
Switch Item Function
3 (On right side
from front)
Input mode (note
1)
Display side NPN
Terminal side PNP
4 (On left side
from front)
Counting speed
(note 1)
Display side 30 Hz
Terminal side 5 kHz
Switch Item Function
3 (On right side
from front)
Input mode
(note 1)
Display side NPN
Te r m i n a l s i d e P N P
4 (On left side
from front)
Time range
(note 1)
Display side 99999.9h
(note 2)
Terminal side 99 h 59 min
59 s
0
0.0h
999999
Total Counters Time Counters
Reset input
Count input
Display
Start input
Display
Reset input
99999.9 h
(see note)
Note: The count value will return to "0" when "999999" is
exceeded.
The display and output are turned OFF when the power
supply turns OFF, but the count value is stored internally.
Note: Display values are shown for full scale set to 99999.9 h.
The count value will return to "0" when "99999.9" is
exceeded.
The display and output are turned OFF when the power
supply turns OFF, but the count value is stored internally.
1. Reset Key
Resets the count value, but will not operate while
the keys are protected.
2. Key Protection Indicator
Lit while the keys are protected. (Reset Key is
disabled.).
3. NPN/PNP DIP Switch
(Count or start with reset)
When the setting has been changed, turned power
off and on to continue. The display will show "0"
when the power is turned back on. See below for
details.
4. Counting Speed DIP Switch (H7GP-C)
Time Range DIP Switch (H7GP-T)
When the setting has been changed, turned power
off and on to continue. The display will show "0"
when the power is turned back on. Refer to DIP
Switch Setting for details.
4
2
1
3
H7GP
6
Dimensions
Note: All units are in millimeters unless otherwise indicated.
In the interest of product improvement, specifications are subject to change without notice.
ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.
To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.
Panel Cutouts
With Flush Mounting Bracket
Terminal cover (provided)
Panel
M3.5 terminal screw
H7GP-C
H7GP-T
Y92S-32 rubber
packing (provided)
Y92F-32 flush mounting
adaptor (provided)
Panel cutouts are as shown below
(according to DIN43700).
Note: 1. The mounting panel thickness should
be 1 to 6 mm.
2. Water resistance will be lost if
Counters are mounted side-by-side.
4. When horizontally mounting Counters
side-by-side, leave at least 50 mm
between any two Counters.
3. The terminal screws are M3.5.
(Theeffective thread length is 6 mm.)
22.2
+0.3
0
45
+0.6
0
22.2
+0.3
0
45
+0.6
0
5.0 min.
50 min.

H7GP-TDB