13
2543MS–AVR–10/16
ATtiny2313
20S
14
2543MS–AVR–10/16
ATtiny2313
20M1
2325 Orchard Parkway
San Jose, CA 95131
TITLE
DRAWING NO.
REV.
20M1, 20-pad, 4 x 4 x 0.8 mm Body, Lead Pitch 0.50 mm,
B
20M1
12/02/2014
2.6 mm Exposed Pad, Micro Lead Frame Package (MLF)
A 0.70 0.75 0.80
A1 – 0.01 0.05
A2 0.20 REF
b 0.18 0.23 0.30
D 4.00 BSC
D2 2.45 2.60 2.75
E 4.00 BSC
E2 2.45 2.60 2.75
e 0.50 BSC
L 0.35 0.40 0.55
SIDE VIEW
Pin 1 ID
Pin #1
Notch
(0.20 R)
BOTTOM VIEW
TOP VIE W
Note:
Reference JEDEC Standard MO-220, Fig. 1 (SAW Singulation) WGGD-5.
COMMON DIMENSIONS
(Unit of Measure = mm)
SYMBOL
MIN
NOM
MAX
NOTE
D
E
e
A2
A1
A
D2
E2
0.08
C
L
1
2
3
b
1
2
3
15
2543MS–AVR–10/16
ATtiny2313
Errata The revision in this section refers to the revision of the ATtiny2313 device.
ATtiny2313 Rev C No known errata
ATtiny2313 Rev B Wrong values read after Erase Only operation
Parallel Programming does not work
Watchdog Timer Interrupt disabled
EEPROM can not be written below 1.9 volts
1. Wrong values read after Erase Only operation
At supply voltages below 2.7 V, an EEPROM location that is erased by the Erase Only oper-
ation may read as programmed (0x00).
Problem Fix/Workaround
If it is necessary to read an EEPROM location after Erase Only, use an Atomic Write opera-
tion with 0xFF as data in order to erase a location. In any case, the Write Only operation can
be used as intended. Thus no special considerations are needed as long as the erased loca-
tion is not read before it is programmed.
2. Parallel Programming does not work
Parallel Programming is not functioning correctly. Because of this, reprogramming of the
device is impossible if one of the following modes are selected:
In-System Programming disabled (SPIEN unprogrammed)
Reset Disabled (RSTDISBL programmed)
Problem Fix/Workaround
Serial Programming is still working correctly. By avoiding the two modes above, the device
can be reprogrammed serially.
3. Watchdog Timer Interrupt disabled
If the watchdog timer interrupt flag is not cleared before a new timeout occurs, the watchdog
will be disabled, and the interrupt flag will automatically be cleared. This is only applicable in
interrupt only mode. If the Watchdog is configured to reset the device in the watchdog time-
out following an interrupt, the device works correctly.
Problem fix / Workaround
Make sure there is enough time to always service the first timeout event before a new
watchdog timeout occurs. This is done by selecting a long enough time-out period.
4. EEPROM can not be written below 1.9 volts
Writing the EEPROM at V
CC
below 1.9 volts might fail.
Problem fix / Workaround
Do not write the EEPROM when V
CC
is below 1.9 volts.
ATtiny2313 Rev A Revision A has not been sampled.

ATTINY2313-20SU

Mfr. #:
Manufacturer:
Microchip Technology / Atmel
Description:
8-bit Microcontrollers - MCU 2kB Flash 0.128kB EEPROM 18 I/O Pins
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union