Parameter Temperature Trends
Figures illustrated in this chapter provide information on the experimental performance of the AUIRS2092S HVIC.
The line plotted in each figure is generated from actual lab data. A large number of individual samples were tested
at three temperatures (-40 ºC, 25 ºC, and 125 ºC) in order to generate the experimental curve. The line consists
of three data points (one data point at each of the tested temperatures) that have been connected together to
illustrate the understood trend. The individual data points on the Typ. curve were determined by calculating the
averaged experimental value of the parameter (for a given temperature).
300
340
380
420
460
-50-25 0 255075100125
Temperature (
o
C)
Turn-on Propagation Delay (ns)
Typ.
Max.
Min.
300
325
350
375
400
-50 -25 0 25 50 75 100 125
Temperature (
o
C)
Turn-off Propagation Delay (ns
Typ.
Max.
Min.
Figure 6: t
ON
vs. temperature Figure 7: t
OFF
vs. temperature
15.0
17.5
20.0
22.5
25.0
-50-250 255075100125
Temperature (
o
C)
Turn-On Rise Time (ns)
Typ.
Max.
Min.
10
15
20
25
30
-50-250255075100125
Temperature (
o
C)
Turn-Off fall Time (ns)
Typ.
Max.
Min.
Figure 8: T
R
vs. temperature Figure 9: T
F