DC and AC Parameters STM1061
16/23
Table 5. DC and AC Characteristics
Sym. Description Test Condition
(1)
1. Valid for Ambient Operating Temperature: T
A
= 25°C.
Min Typ Max Unit
V
CC
Operating Voltage 0.7 6.0 V
I
CC
V
CC
Supply Current
V
CC
= 3.0V, No Load 0.9 3.0 µA
V
CC
= 5.5V, No Load 1.1 3.6 µA
I
OUT
Output Current, N-channel
(V
DS
= 0.5V),
Reset asserted
V
CC
= 1.0V 1.0 1.7 mA
V
CC
= 2.0V 3.0 14 mA
V
CC
= 3.0V 5.0 22 mA
V
CC
= 4.0V 6.0 26 mA
V
CC
= 5.0V 7.0 30 mA
Voltage Thresholds
V
TH–
Detect Voltage
(2)
(see Table 9 on page 21 for
detailed listing)
2. Other V
TH-
threshold are offered. Minimum order quantities may apply. Contact local sales office for availability.
V
TH–
– 2% V
TH–
V
TH–
+ 2% V
V
TH+
Release Voltage
V
TH–
+
V
HYST
V
V
HYST
Threshold Hysteresis 0.02V
TH–
0.05V
TH–
0.08V
TH–
V
t
PD
V
CC
to OUT Detect Delay
V
CC
falling from (V
TH–
+ 100mV) to (V
TH–
–
100mV)
at 10mV/µs
25 µs
t
PR
V
CC
to OUT Release Delay
V
CC
rising from (V
TH+
– 100mV) to (V
TH+
+
100mV)
at 10mV/µs
30 200 µs
Threshold Temperature
Coefficient
±100 ppm/
o
C