LXMG2203
PRODUCTION DATASHEET
LXMG221D-0700040-D2F
Microsemi
Analog Mixed Signal Group
11861 Western Avenue, Garden Grove, CA. 92841, 800-877-6458, 714-898-8121, Fax: 714-893-2570
Page 4
Copyright © 2011
Rev. 1.1, 2011-12-02
40W 700mA Dimmable HV LED Driver Module
TM
®
WWW.Microsemi .COM
L
L
X
X
M
M
G
G
2
2
2
2
1
1
D
D
-
-
0
0
7
7
0
0
0
0
0
0
4
4
0
0
-
-
D
D
2
2
F
F
Safety & EMC Compliance
UL Compliance to UL8750 & UL1310 Class 2 File E337545
FCC Title 47, Part 15 Conducted and Radiated Emission, Class B
EN 61000-3-3 Voltage fluctuations and flicker
EN61000-4-2 Electrostatic Discharge Immunity
EN61000-4-3 Radiated Susceptibility test
EN61000-4-4 Electrical Fast Transient
EN61000-4-5 and ANSI C61.42.2 Surge Immunity Test, AC Power Line, Category C Low Exposure (6kV/3kV)
EN61000-4-6 Conducted Susceptibility Immunity test
EN61000-4-8 Power Frequency Magnetic Field Immunity Test
EN61000-4-11 Voltage Dips and Interruption Immunity
Life Expectancy 5 years / 50,000 hours @ 100% duty at maximum case temperature 55°C
MTBF
221,569 hours, case temperature 55°; 121,565 hours case temperature 70°C
Bellcore TR-NWT-332, Issue 6; Method 1, Case 3, Ground Benign
Environmental Standards EU RoHS, REACH
LEAD DESCRIPTION
Name Pin # Description
INPUT TERMINAL LEADS (18AWG)
BLACK AC LINE Main Input Power Supply Line 347V
AC
to 480V
AC
WHITE AC NEUTRAL Main Input Power Supply Neutral
CONTROL TERMINAL LEADS (22AWG)
PURPLE BRITE A Analog Dimming Input (Full Brightness if Open)
GRAY RETURN RETURN
BROWN FAULT Fault Signal (Low During Whole LED String Short or Open)
OUTPUT TERMINAL LEADS (18AWG)
RED OUTPUT(+) LED String Anode Voltage (High Side)
BLUE OUTPUT(-) OUTPUT (-) LED Cathode Voltage (Low Side) 700mA
FAULT TABLE
CONDITION OUTPUT(-)
FAULT
DRIVER STATUS
COMMENT
OUTPUT(+) String OUTPUT (-)
(700mA)
ON Hi-Z ON
OUTPUT(+) OPEN OUT(-) OPEN LOW OUTPUT(+) Max Voltage
OUTPUT(+) Short OUT(-) OPEN LOW SHUTDOWN
OUTPUT(+) String OUTPUT (-) w/
1 or more LED short
ON Hi-Z ON
STAYLIT™, OUTPUT(+) ≥ 20V
Over Temperature at the Case
Hot Spot
OPEN LOW SHUTDOWN
When the temperature goes
down, the module turns on
again (no user intervention)
Power Loss (Blackout) Event OPEN LOW SHUTDOWN
When Power comes back, the
module turns on again (no user
intervention)
BRITE A Shorted TO RETURN or
OUTPUT(-)
OPEN Hi-Z SHUTDOWN
BRITE A OPEN (or Resistor >
12kOhm)
ON Hi-Z ON