14. In order that power can be turned OFF in an emergency by
the person operating the Temperature Controller, install the
appropriate switches and circuit breakers, and label them
accordingly.
15. Turn OFF the power before drawing out the Temperature
Controller body. Do not touch or apply excessive force to the
terminals or electronic parts. When inserting the body, make
sure that electronic parts do not come in contact with the
case.
16. When the terminal block for the E5GN is detached, do not
touch or apply excessive force to any electronic parts.
17. Use alcohol to clean the Temperature Controller. Do not use
thinner or other solvent-based substances.
18. Inverters with an output frequency of 50/60 Hz are available,
but they may cause the internal temperature of Temperature
Controller to rise, possibly resulting in smoke or burning. Do
not use an inverter output to supply power to a Temperature
Controller.
Service Life
1. Use the Temperature Controller within the specified temperature
and humidity ranges. If the product is installed inside a control
panel, the temperature around the Temperature Controller and
not the temperature around the control panel must be kept within
the specified temperature range.
2. The service life of electronic devices such as Temperature
Controllers is determined not only by the number of switching
operations performed by the relay, but also by the service life
of the internal electronic components. The service life of
these components depends on the ambient temperature: it
will be shorter if the ambient temperature is high and longer if
the ambient temperature is low. For this reason, the service
life of the product can be extended by keeping the internal
temperature of the Temperature Controller low.
3. If several Temperature Controllers are mounted side-by-side
or are arranged vertically, the heat generated by them may
cause the internal temperature of the products to rise, thus
reducing their service life. To prevent this, take steps to
ensure that the Temperature Controllers are cooled, such as
installing fans. When providing forced cooling, however, be
careful not to cool down the terminal sections alone to avoid
measurement errors.
Measurement Accuracy
1. When extending the lead wires for thermocouples, use a com-
pensating conductor appropriate for the type of thermocouple
use.
2. When extending the lead wires for platinum resistance ther-
mometers, use lead wires with low resistance, and make the
resistance in the 3 lead wires equal.
3. The type of Temperature Sensor and the input type for the
Temperature Controller must be set the same.
4. There are two types of platinum resistance thermometers: Pt
and JPt. Accurate measurement will not be possible if the
input type for the Temperature Sensor is not set correctly.
5. Mount the Temperature Controller horizontally.
6. If significant errors occur, check to see if the input shift has
been set correctly.
Waterproofing
Sections without any specification on their degree of protection or
those with IP@0 specifications are not waterproof.
EN/IEC Compliance
Installing the following fuse in the power supply terminal block is rec-
ommended if the Temperature Controller is used in applications
requiring EN/IEC compliance.
Recommended fuse: A T2A, 250-VAC, time lag fuse with low break-
ing capacity
Operating Precautions
1. It takes approximately five seconds for the outputs to turn ON
from the moment the power is turned ON. Due consideration
must be given to this time when incorporating Temperature Con-
trollers in a sequence circuit.
2. When using the self-tuning capability of the E5@N, E5@K, or
E5@J, supply power to the load (e.g., heater) at the same
time as or before supplying power to the Temperature Con-
troller. If power is turned ON for the Temperature Controller
before turning ON power for the load, self-tuning will not be
performed properly and optimum control will not be achieved.
When starting operation after the Temperature Controller has
warmed up, turn OFF the power and then turn it ON again at
the same time as turning ON power for the load. (Instead of
turning the Temperature Controller OFF and ON again,
switching from STOP mode to RUN mode can also be used in
this case.)
3. The reception of the Temperature Controller may be affected
if it is used close to radios, television sets or wireless
devices.
Precautions for Correct Use
http://www.ia.omron.com/
C-3
(c)Copyright OMRON Corporation 2007 All Rights Reserved.
3
The following displays are use to represent the characters for parameter names on the Temperature Controller.
Seven-segment Digital DIsplay
Eleven-segment Digital Display
Parameter Displays
ABCDEFGH I J KLMNOPQRSTUVWXYZ
ABCDEFGH I JKLMNOPQRSTUVWXYZ
ab cde fgh ijk lm nopq rstuvw xyz
In the interest of product improvement, specifications are subject to change without notice.
ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.
To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.
2007.3
OMRON Corporation
Industrial Automation Company
http://www.ia.omron.com/
(c)Copyright OMRON Corporation 2007 All Rights Reserved.
In the interest of product improvement, specifications are subject to change without notice.
Read and Understand This Catalog
Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or
comments.
Warranty and Limitations of Liability
WARRANTY
OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if
specifi ed) from date of sale by OMRON.
OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR
FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS
DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. OMRON DISCLAIMS ALL OTHER
WARRANTIES, EXPRESS OR IMPLIED.
LIMITATIONS OF LIABILITY
OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS, OR COMMERCIAL
LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR
STRICT LIABILITY.
In no event shall responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted.
IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS
OMRON'S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT
SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR.
Application Considerations
SUITABILITY FOR USE
OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the customer's
application or use of the product.
At the customer's request, OMRON will provide applicable third party certifi cation documents identifying ratings and limitations of use that apply to the
products. This information by itself is not suf cient for a complete determination of the suitability of the products in combination with the end product,
machine, system, or other application or use.
The following are some examples of applications for which particular attention must be given. This is not intended to be an exhaustive list of all possible
uses of the products, nor is it intended to imply that the uses listed may be suitable for the products:
• Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this catalog.
• Nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles, safety
equipment, and installations subject to separate industry or government regulations.
• Systems, machines, and equipment that could present a risk to life or property.
Please know and observe all prohibitions of use applicable to the products.
NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE
SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCT IS PROPERLY RATED AND
INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM.
Disclaimers
CHANGE IN SPECIFICATIONS
Product speci cations and accessories may be changed at any time based on improvements and other reasons.
It is our practice to change model numbers when published ratings or features are changed, or when signifi cant construction changes are made.
However, some speci cations of the product may be changed without any notice. When in doubt, special model numbers may be assigned to fi x
or establish key specifi cations for your application on your request. Please consult with your OMRON representative at any time to confi rm actual
specifi cations of purchased product.
DIMENSIONS AND WEIGHTS
Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown.
ERRORS AND OMISSIONS
The information in this catalog has been carefully checked and is believed to be accurate; however, no responsibility is assumed for clerical,
typographical, or proofreading errors, or omissions.
PERFORMANCE DATA
Performance data given in this catalog is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent
the result of OMRON’s test conditions, and the users must correlate it to actual application requirements. Actual performance is subject to the OMRON
Warranty and Limitations of Liability.
PROGRAMMABLE PRODUCTS
OMRON shall not be responsible for the user's programming of a programmable product, or any consequence thereof.
COPYRIGHT AND COPY PERMISSION
This catalog shall not be copied for sales or promotions without permission.
This catalog is protected by copyright and is intended solely for use in conjunction with the product. Please notify us before copying or reproducing this
catalog in any manner, for any other purpose. If copying or transmitting this catalog to another, please copy or transmit it in its entirety.

E5EK-AA2-500 AC/DC24

Mfr. #:
Manufacturer:
Omron Automation and Safety
Description:
Controllers 1/8 DIN 240VAC STANDARD MODEL
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union