PJT-12V40WBAA

TECHNICAL DATASHEET
PJT Open Frame Power
Supply
PJT-40W Series
/ PJT-
□□
V40WBA
All parameters are specified at 25°C ambient unless otherwise indicated.
www.DeltaPSU.com (April 2016, Rev. 01)
4
EMC
EMC / Emissions CISPR 22, EN 55022, FCC Title 47: Class B
Immunity to EN 55024
Electrostatic Discharge IEC 61000-4-2 Criteria A
1)
Level 3 Air Discharge: 8kV
Level 3 Contact Discharge: 6kV
Radiated Field IEC 61000-4-3 Level 2 Criteria A
1)
80MHz-1GHz, 3V/M with 1kHz tone / 80% modulation
Electrical Fast Transient / Burst IEC 61000-4-4 Level 3 Criteria A
1)
2kV
Surge IEC 61000-4-5 Level 3 Criteria A
1)
Common Mode
2)
: 2kV
Differential Mode
3)
: 1kV
Conducted IEC 61000-4-6 Level 2 Criteria A
1)
3V with 80% AM
Power Frequency Magnetic Fields IEC 61000-4-8 Criteria A
1)
Magnetic field strength 3A/Meter
Voltage Dips IEC 61000-4-11 30% dip; 10ms Criterion A
60% dip; 100ms Criterion B
95% dip; 5000ms Criterion B
Voltage Fluctuation and Flicker IEC/EN 61000-3-3
1) Criteria A: Normal performance within the specification limits
2) Asymmetrical: Common mode (Line to earth)
3) Symmetrical: Differential mode (Line to line)
Block Diagram
TECHNICAL DATASHEET
PJT Open Frame Power
Supply
PJT-40W Series
/ PJT-
□□
V40WBA
All parameters are specified at 25°C ambient unless otherwise indicated.
www.DeltaPSU.com (April 2016, Rev. 01)
5
Dimensions
L x W x D: 76.2 x 50.8 x 22.9 mm [2” x 3”]
Item
Device Description
1 Input Connector (CN1)
Pin 1: Line
Pin 2: NC
Pin 3: Neutral
2
Output Connector (CN2)
Pin 1 to 2 : V(+)
Pin 3 to 4 : V(-)
1
3
4
1
TECHNICAL DATASHEET
PJT Open Frame Power
Supply
PJT-40W Series
/ PJT-
□□
V40WBA
All parameters are specified at 25°C ambient unless otherwise indicated.
www.DeltaPSU.com (April 2016, Rev. 01)
6
Engineering Data
Output Load De-rating VS Surrounding Air Temperature
Output Load De-rating VS Input Voltage
Note
1. Power supply components may degrade, or
be damaged, when the power supply is
continuously used outside the shaded region,
refer to the graph shown in Fig. 1.
2. If the output capacity is not reduced when the
surrounding air temperature >50
°C, the
device will run into Over Temperature
Protection. When activated, the output
voltage will go into bouncing mode and will
recover when the surrounding air
temperature is lowered or the load is reduced
as far as necessary to keep the device in
working condition.
3.
Depending on the surrounding air
temperature and output load delivered by the
power supply, the device can be very hot!
4. If the device has to be mounted in any other
orientation, please contact
info@deltapsu.com for more details.
Fig. 1 De-rating for Horizontal Mounting Orientation
> 50°C de-rate power by 2.5% / °C
No output power de-rating for the input
voltage from 90Vac to 264Vac

PJT-12V40WBAA

Mfr. #:
Manufacturer:
Description:
Switching Power Supplies 12V 40W 2x3" Chassis Open Frame/JST Conn.
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union